Author: Zhao, Y.
Paper Title Page
MOAB2 Overview of Beam Instrumentation for the CADS Injector I Proton Linac 21
 
  • Y.F. Sui, J.S. Cao, Q.Y. Deng, J. He, H.Z. Ma, L. Wang, Q. Ye, L. Yu, J.H. Yue, X.Y. Zhao, Y. Zhao
    IHEP, Beijing, People's Republic of China
 
  The driver linac of the China Accelerator Driven Subcritical system (C-ADS), which is composed of an ECR ion source, a low energy beam transport line (LEBT), a radio frequency quadrupole accelerator (RFQ), a medium energy beam transport line (MEBT) and cryomodules with SRF cavities to boost the energy up to 10 MeV. The injector linac will be equipped with beam diagnostics to measure the beam position, the transverse profile and emittance, the beam phase as well as beam current and beam losses. Though many are conventional design, They can provide efficient operation of drive linac. This paper gives an overview of C-ADS linac beam instrumentation.  
slides icon Slides MOAB2 [2.755 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2015-MOAB2  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPF057 Beam Commissioning of C-ADS Injector-I RFQ Accelerator 3827
 
  • C. Meng, J.S. Cao, Y.Y. Du, H. Geng, T.M. Huang, R.L. Liu, H.F. Ouyang, W.M. Pan, S. Pei, H. Shi, Y.F. Sui, J.L. Wang, S.C. Wang, F. Yan, Q. Ye, L. Yu, Y. Zhao
    IHEP, Beijing, People's Republic of China
 
  The C-ADS accelerator is a CW (Continuous-Wave) proton linac with 1.5 GeV in beam energy, 10 mA in beam current, and 15 MW in beam power. C-ADS Injector-I accelerator is a 10-mA 10-MeV CW proton linac, which uses a 3.2-MeV normal conducting 4-Vane RFQ and superconducting single-spoke cavities for accelerating. The frequency of RFQ accelerator is 325 MHz. The test stand composed of an ECR ion source, LEBT, RFQ, MEBT and beam dump have been installed and the first stage of beam commissioning have been finished at IHEP in 2014 mid-year. At 90% duty factor, we got 11 mA proton beam at RFQ exit with 90% beam transmission efficiency, while 95% beam transmission efficiency at 70% duty factor. The energy after RFQ was measured by TOF method with FCTs. The transverse emittance measured by double-slits emittance meter was 0.135 π mm-mrad, which of detailed data analysis will be presented in this paper.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2015-THPF057  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)