Author: Zhang, Z.
Paper Title Page
WEPMN003 The Magnetic Measurement for Low Magnetic Field Stability of Dipole Magnet for CEPC 2917
 
  • Z. Zhang, F.S. Chen, H. Geng, B. Yin
    IHEP, Beijing, People's Republic of China
 
  The CEPC (China Electron-Positron Collider) project is in the pre-research stage. When the beam energy of booster is 120 GeV, the magnetic field of deflection magnet is 640 G. In order to save funds for scientific research, we are ready to select the injection energy for 6 GeV, this corresponds to a magnetic field about 32 G. In such a low magnetic field, the effects of earth's magnetic field and ambient temperature variations cannot be ignored. In this paper, first written the collection procedures for magnetic field value and ambient temperature values by Labview software, then used a one-dimensional probe to measure the background magnetic field for three directions (Bx, By, Bz) and the value of the ambient temperature values, the time of data collection for each direction are more than 24 hours (every minute collecting a set of values). Finally, plus the different currents (3A, 6A.. 15A) to the dipole magnet, the time of measured and the data collected by over 24 hours. Based on the results of the analysis of large amounts of data, summarized and analyzed the effect of Earth's magnetic field and ambient temperature for dipole magnet in a low magnetic field.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2015-WEPMN003  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)