MOPTY011 Operation Experience of p-Carbon Polarimeter in RHIC 956
 
  • H. Huang, E.C. Aschenauer, G. Atoian, A. Bazilevsky, O. Eyser, D. Kalinkin, J. Kewisch, Y. Makdisi, S. Nemesure, A. Poblaguev, W.B. Schmidke, D. Smirnov, D. Steski, K. Yip, A. Zelenski
    BNL, Upton, Long Island, New York, USA
  • I.G. Alekseev, D. Svirida
    ITEP, Moscow, Russia
 
  Funding: Work supported by Brookhaven Science Associates, LLC under Contract No. DE-AC02-98CH10886 with the U.S. Department of Energy.
The spin physics program in Relativistic Heavy Ion Collider (RHIC) requires fast polarimeter to monitor the polarization evolution on the ramp and during stores. Over past decade, the polarimeter has evolved greatly to improve its performance. These include dual chamber design, monitoring camera, Si detector selection (and orientation), target quality control, and target frame modification. The preamp boards have been modified to deal with the high rate problem, too. The ultra thin carbon target lifetime is a concern. Simulations have been carried out on the target interaction with beam. Modification has also been done on the frame design. Extra caution has been put on RF shielding to deal with the pickup noises from the nearby stochastic cooling kickers. This paper summarizes the recent operation performance of this delicate device.
 