MOPTY057 Feasibility Study of Monitoring the Population of the CERN-LHC Abort Gap with Diamond Based Particle Detectors 1065
 
  • O. Stein, F. Burkart, B. Dehning, R. Schmidt, C.B. Sørensen, D. Wollmann
    CERN, Geneva, Switzerland
 
  At the end of a physics fill and in case of a failure, the LHC beams must be extracted and transferred through a 750m long line to the beam dump block. During the rise of the extraction kickers to their full strength a particle-free abort gap, with a length of 3 us in the LHC filling pattern, is required to prevent beam losses that could lead to substantial quenching of magnets, with a risk of damage. Therefore the particle population in the abort gap, which is mainly due to un-bunched beam, is monitored. Above a certain threshold an active cleaning by excitation of betatron oscillations with the transverse feedback system is initiated. This paper describes a novel method of monitoring the abort gap population using diamond particle detectors for detecting the interactions of beam in the abort gap with neon gas, injected in the beam pipe. Two different layouts of the system and the expected interaction and detection rates are discussed.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2015-MOPTY057  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPTY058 Response of Polycrystalline Diamond Particle Detectors Measured with a High Intensity Electron Beam 1069
 
  • O. Stein, F. Burkart, B. Dehning, R. Schmidt, C.B. Sørensen, D. Wollmann
    CERN, Geneva, Switzerland
  • E. Griesmayer
    CIVIDEC Instrumentation, Wien, Austria
 
  Comprehensive understanding of beam losses in the LHC is required to ensure full machine protection and efficient operation. The existing BLM system using ionization chambers is not adequate to resolve losses with a time resolution below some 10 us. Ionization chambers are also not adequate to measure very large transient losses, e.g. beam impacting on collimators. Diamond particle detectors with bunch-by-bunch resolution have therefore been used in LHC to measure fast particle losses with a time resolution down to a level of single bunches. Diamond detectors have also successfully been used for material damage studies in other facilities, e.g. HiRadMat at the CERN-SPS. To fully understand their potential, such detectors were characterized with an electron beam at the BTF in LNF INFN Italy, with bunch intensities from 103 to 109 electrons. The detector response and efficiency has been measured with a 50 Ω and a 1 Ω read-out system. This paper describes the experimental setup and the results of the experiment. In particular, the responses of three samples of 100 um single-crystalline diamond detectors and two samples of 500 um polycrystalline diamond detectors are presented.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2015-MOPTY058  