Paper |
Title |
Page |
MOPWA041 |
Investigation of Radiation Damage of Insertion Devices at PETRA III due to Particle Losses using Tracking Results with SixTrack |
203 |
|
- G.K. Sahoo, M. Bieler, J. Keil, A. Kling, G. Kube, M. Tischer, R. Wanzenberg
DESY, Hamburg, Germany
|
|
|
PETRA-III is a 3rd generation synchrotron light source dedicated to users at 14 beam lines with 30 instruments since 2009. This operates in 40, 60, 480 or 960 bunches with 100 mA at an electron beam energy of 6 GeV. The horizontal beam emittance is 1nmrad while a coupling of 1% amounts to a vertical emittance of 10 pm-rad. The low emittance is achieved by deploying 80m of damping wigglers in two sections in west and north. Some of these undulators and wiggler devices have accumulated total radiation doses of about 100 kGy. Visible corrosion at the magnet structures of some permanent magnet undulators is seen. High dose rate measured regularly by Thermo Luminescent Dosimeters (TLDs) are monitored, which lead to inspect the magnetic field of all insertion devices in the PETRA tunnel. We are investigating particle losses with tracking simulation using SixTrack to gain a certain understanding of the radiation damage of the insertion devices. The goal is to develop a strategy to safeguard the insertion devices from further radiation damage.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2015-MOPWA041
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
TUPWA034 |
Status of the Recommissioning of the Synchrotron Light Source PETRA III |
1485 |
|
- R. Wanzenberg, M. Bieler, M. Ebert, L. Fröhlich, J. Keil, J. Klute, G. Kube, G.K. Sahoo
DESY, Hamburg, Germany
|
|
|
At DESY the Synchrotron Light Source PETRA III has been extended in the North and East section of the storage ring to accommodate ten additional beam lines. The PETRA ring was converted into a dedicated synchrotron light source from 2007 to 2009. Regular user operation started in summer 2010 with a very low emittance of 1 nm at a beam energy of 6 GeV and a total beam current of 100 mA. All photon beamlines were installed in one octant of the storage ring. Nine straight sections facilitated the installation of insertion devices for 14 beam lines. Due to the high demand for additional beamlines the lattice of the ring was redesigned to accommodate 10 additional beamlines in the future. In a one year long shut-down two new experimental halls were built. The recommissioning of PETRA III started in February 2015. We are reporting the current status of synchrotron light source including the performance of the subsystems.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2015-TUPWA034
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|