Author: May-Mann, J.
Paper Title Page
WEPTY068 Asymmetric Thermo-currents Diminishing SRF Cavity Performance 3437
 
  • R.G. Eichhorn, J. May-Mann
    Cornell University (CLASSE), Cornell Laboratory for Accelerator-Based Sciences and Education, Ithaca, New York, USA
 
  Over the past years it became evident that the quality factor of a superconducting cavity is not only determined by its surface preparation procedure, but is also influenced by the way the cavity is cooled down. In this paper we will present results from numerical field calculations of magnetic fields produced by thermo-currents, driven by temperature gradients and material transitions. We will show how they can impact the quality factor of a cavity by producing a magnetic field at the RF surface of the cavity.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2015-WEPTY068  