Paper |
Title |
Page |
MOPTY048 |
Machine Protection Strategy for the ESS |
1042 |
|
- A. Nordt, T. Friedrich, T. Korhonen
ESS, Lund, Sweden
- C. Hilbes
ZHAW, Winterthur, Switzerland
|
|
|
The ESS proton beam power of 125MW per pulse (5MW average) will be unprecedented and its uncontrolled release could lead to serious damage of equipment within a few microseconds only. To optimize the operational efficiency of the ESS facility allowing for very high beam availability with high reliability towards the end-users, accidents should be avoided and interruptions of beam operation have to be rare and limited to a short time. Finding the right balance between efficient protection of equipment from damage and high beam availability is the key idea on which the ESS Machine Protection Strategy is being based on. Implementing and realizing the measures needed to provide the correct level of machine protection in case of a complex facility like the ESS, requires a systematic approach, which will be discussed in this paper. A method of how to derive machine protection relevant requirements and how to assure completeness of these will be outlined as well.
|
|