Paper | Title | Page |
---|---|---|
WEPMN039 | RF Accelerating Voltage of PLS-II Superconducting RF System for Stable Top-up Operation with Beam Current of 400 mA | 3015 |
|
||
During the beam store test up to 400 mA in the storage ring, it was observed that the vacuum pressure around the RF window of the superconducting cavity rapidly increases over the interlock level limiting the availability of the maximum beam current storing. We investigated the cause of the window vacuum pressure increment by studying the changes in the electric field distribution at the superconducting cavity and waveguide according to the beam current. An equivalent physical modeling was developed using a finite-difference time-domain (FDTD) simulation and it revealed that the electric field amplitude at the RF window is exponentially increased as the beam current increases, thus this high electric field amplitude causes a RF breakdown at the RF window. | ||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2015-WEPMN039 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
WEPMN042 | 400 mA Beam Store with Superconducting RF Cavities at PLS-II | 3021 |
|
||
Funding: Minister of Science, ICT and Future Planning Three superconducting RF cavities were commissioned with electron beam in way of one by one during the last 3 years, and now PLS-II is in user service on the way of beam current to 400mA, the target of PLS-II. The cavities and cryomodules were prepared with SRF standard technology and procedures, then vertical test, windows conditioning, cryogenic test in each cryomodule, horizontal power test, conditioning, and commissioning without and with beam at PLS-II tunnel by collaboration with industries. All the cavities showed stable performances as good as not-observing any RF instability from cavities, couplers and windows up to 400 mA beam store, but observing several cavity quenches and minor vacuum bursts by abrupt power with control and human errors. The initial beam current for user run were recorded as 150 mA with one cavity, 280 mA with two cavities and 320 mA with three cavities. The 400 mA beam was also achieved with two cavities by decay mode and also with three cavities by top-up mode. The stabilities of RF amplitude and phase are good enough not to induce beam instabilities. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2015-WEPMN042 | |