Keyword: data-acquisition
Paper Title Other Keywords Page
MOPME062 The Acceptance Measurement Platform for TPS Corrector Magnet Power Supplies interface, power-supply, controls, feedback 514
 
  • B.S. Wang, Y.-C. Chien, C.-Y. Liu, K.-B. Liu, Y.S. Wong
    NSRRC, Hsinchu, Taiwan
 
  This paper presents an implementation of a multi-channel measuring data acquisition interface of corrector magnet power supplies (CMPS) for Taiwan Photon source (TPS) with LabVIEW as the developing tool. The multi-channel measuring data acquisition interface could reduce quantity of measurement instrument and loading of operator at the CMPS acceptance test. The instrument devices of measurement system include a multiplexer 、a dynamic signal analyzer (DSA) and a high-resolution digital voltage meter (DVM), GPIB is the communication interface between the multi-channel measuring data acquisition interface and instruments. There are two analyzing procedure for the output current of MPS in the default setting of the LabVIEW program, 1) Fast Fourier Transform of output current measured by DSA, 2) long-term stability of output current measured by DVM; after these two analyzing procedure is completed, the performance of each MPS can be automatically generated as a Microsoft Word report file.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-MOPME062  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPRO125 Synchronous Data Acquisition System for TPS and its Applications ground-motion, emittance, site, interface 3186
 
  • C.H. Huang, Y.-S. Cheng, P.C. Chiu, K.T. Hsu, S.H. Lee, C.Y. Liao, C.Y. Wu
    NSRRC, Hsinchu, Taiwan
 
  Orbit stability in 100 nm range is essential for a very small emittance synchrotron light source. However, all kinds of vibration source such as cultural noise and technical noise might deleterious the orbit stability. A synchronous data acquisition system is promising to study connection of orbit motion and various vibration related sources. In this report, we present a synchronous data acquisition system which integrates the measurement of beam position and vibration and then this system will deploy for the Taiwan Photon Source (TPS). To test the applicability of the system, systematic study orbit motion caused by vibration using this system was performed at Taiwan Light Source (TLS). Preliminary results will summary in this report.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPRO125  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)