MOPME039 A New Method of Acquiring Fast Beam Transversal Profile in the Storage Ring 556
 
  • C. Cheng, P. Lu, B.G. Sun, K. Tang, F.F. Wu, Y.Y. Xiao, Y.L. Yang, Z.R. Zhou, J.Y. Zou
    USTC/NSRL, Hefei, Anhui, People's Republic of China
 
  A new method of acquiring fast beam transverse profile has been developed and will be used in HLS II. This method is based on four signals from MAPMT (multi-anode photo-multiplier tube) and logarithm processing technique. First, the calculation formula of beam transversal size and position are deduced using above method. Then, the main performances (e.g. sensitivity and linearity range) are analyzed. According to stimulation result, regardless of cross-talk and inconsistency between channels, the size signal has a linear relation with size s when s=0.8-2mm and position d=±2mm, the position signal has a linear relation with position d and the linear range exceeds ±2mm when s=0.8-2mm. With channel cross-talk and channel inconsistency being considered, the stimulation results also are given. Finally, a fast beam transverse profile monitor is designed and provides turn-by-turn measurement of the beam transverse profile.  
 
MOPME042 A PRELIMINARY SIMULATION OF BPM SIGNAL DIODE DETECTOR FOR HLS II TUNE MEASUREMENT SYSTEM* 565
 
  • J.J. Zheng, P. Lu, T.J. Ma, B.G. Sun, Y.L. Yang, J.Y. Zou
    USTC/NSRL, Hefei, Anhui, People's Republic of China
 
  Funding: Supported by National Natural Science Foundation of China (11105141, 11175173) and the Fundamental Research Funds for the Central Universities (WK2310000015)
A high sensitivity BPM signal detection front-end electronics has been designed for HLS II tune measurement system according to the HLS II upgrade requirements. Classical tune measurement systems filter out just one or a few of these betatron sidebands frequency. As a consequence, most of the betatron energy is dropped and only a very small energy remains for further processing. A new method, referred to as Direct Diode Detection (3D) by LHC[1], improves the situation. In this paper, the HLS II BPM signals have been calculated out in time domain and frequency domain. Basing on the characteristics of HLS II BPM signal, a preliminary simulation is performed to test and verify the feasibility of diode detector for HLS II tune measurement system. The simulation results clearly show that the technique of diode-based circuit can be applied to HLS II tune measurement.
 
 
MOPME043 Calibration of Beam Position Monitors in the Injector of HLS II 568
 
  • J.Y. Zou, J. Fang, W.B. Li, P. Lu, T.J. Ma, B.G. Sun, Y.L. Yang, Z.R. Zhou
    USTC/NSRL, Hefei, Anhui, People's Republic of China
 
  Funding: Supported by the National Science Foundation of China (11175173, 11105141)
A beam position monitor(BPM) system is being installed to improve the beam position measurement of the injector at the upgrade project of Hefei Light Source (HLS II). The new BPM system is consists of 19 stripline BPMs and 19 Libera Brilliance Single Pass modules. Before installation, the response of the BPMs must be mapped to improve the accuracy of measurement. The theoretical equations of both position and quadrupole component of the BPM are calculated first, using both formula and matlab simulation. A laboratory calibration system is built. The inconsistency of Libera Brilliance Single Pass channels is measured to improve the accuracy of calibration. The calibrating results show the position sensitivity is less than 5% difference compare to the theoretical value, while the quadrupole component sensitivity is less than 10% difference.