Author: Quigley, P.
Paper Title Page
WEPWO059 Cornell's HOM Beamline Absorbers 2441
 
  • R. Eichhorn, J.V. Conway, Y. He, G.H. Hoffstaetter, M. Liepe, T.I. O'Connell, P. Quigley, J. Sears, V.D. Shemelin, N.R.A. Valles
    CLASSE, Ithaca, New York, USA
 
  The proposed energy recovery linac at Cornell aims for high beam currents and short bunch lengths, the combination of which requires efficient damping of the higher order modes (HOMs) being present in the superconducting cavities. Numerical simulations show that the expected HOM power could be as high as 200 W per cavity with frequencies ranging to 40 GHz. Consequently, a beam line absorber approach was chosen. We will review the design, report on first results from a prototype and discuss further improvements.  
 
WEPWO060 The CW Linac Cryo-module for Cornell’s ERL 2444
 
  • R. Eichhorn, Y. He, G.H. Hoffstaetter, M. Liepe, T.I. O'Connell, P. Quigley, D.M. Sabol, J. Sears, E.N. Smith, V. Veshcherevich
    CLASSE, Ithaca, New York, USA
 
  Cornell University has proposed an energy-recovery linac (ERL) based synchrotron-light facility which can provide greatly improved X-ray beams due to the high electron-beam quality that is available from a linac. As part of the phase 1 R&D program, critical challenges in the design were addressed, one of them being a full linac cryo-module. It houses 6 superconducting cavities- operated at 1.8 K in cw mode- HOM absorbers and a magnet/ BPM section. We will present the design being finalized recently and report on the fabrication status that started in late 2012.  
 
WEPWO061 Readiness for the Cornell ERL 2447
 
  • G.H. Hoffstaetter, A.C. Bartnik, I.V. Bazarov, D.H. Bilderback, M.G. Billing, J.D. Brock, J.A. Crittenden, L. Cultrera, D.S. Dale, J. Dobbins, B.M. Dunham, R.D. Ehrlich, M. P. Ehrlichman, R. Eichhorn, K. Finkelstein, E. Fontes, M.J. Forster, S.J. Full, F. Furuta, D. Gonnella, S.W. Gray, S.M. Gruner, C.M. Gulliford, D.L. Hartill, Y. He, R.G. Helmke, K.M.V. Ho, R.P.K. Kaplan, S.S. Karkare, V.O. Kostroun, H. Lee, Y. Li, M. Liepe, X. Liu, J.M. Maxson, C.E. Mayes, A.A. Mikhailichenko, H. Padamsee, J.R. Patterson, S.B. Peck, S. Posen, P. Quigley, P. Revesz, D.H. Rice, D. Sagan, J. Sears, V.D. Shemelin, D.M. Smilgies, E.N. Smith, K.W. Smolenski, A.B. Temnykh, M. Tigner, N.R.A. Valles, V. Veshcherevich, A.R. Woll, Y. Xie, Z. Zhao
    CLASSE, Ithaca, New York, USA
 
  Funding: Supported by NSF award DMR-0807731 and NY State
Energy-Recovery Linacs (ERLs) are proposed as drivers for hard x-ray sources because of their ability to produce electron bunches with small, flexible cross sections and short lengths at high repetition rates. Cornell University has pioneered the design and hardware for ERL lightsources. This preparatory research for ERL-lightsource construction will be discussed. Important milestones have been achieved in Cornell's prototype ERL injector, including the production of a prototype SRF cavity that exceeds design specifications, the regular production of long-lived and low emittance cathodes, the acceleration of ultra-low emittance bunches, and the world-record of 65 mA current from a photoemission DC gun. We believe that demonstration of the practical feasibility of these technologies have progressed sufficiently to allow the construction of an ERL-based lightsource like that described in [erl.chess.cornell.edu/PDDR].
 
 
WEPWO068 Cornell ERL Main Linac 7-cell Cavity Performance in Horizontal Test Cryomodule Qualifications 2459
 
  • N.R.A. Valles, R. Eichhorn, F. Furuta, G.M. Ge, D. Gonnella, Y. He, K.M.V. Ho, G.H. Hoffstaetter, M. Liepe, T.I. O'Connell, S. Posen, P. Quigley, J. Sears, V. Veshcherevich
    CLASSE, Ithaca, New York, USA
 
  Funding: NSF DMR-0807731
Cornell has recently finished producing and testing the first prototype 7-cell main linac cavity for the Cornell Energy Recovery Linac, and completed the prototype cavity qualification program. This paper presents quality factor results from the horizontal test cryomodule (HTC) measurements, from the HTC-1 through HTC-3 experiments, reaching Q's up to 6 x 1010 at 1.6 K. We investigate the effect of thermal cycling on cavity quality factor and show that high quality factors can be preserved from initial mounting to fully outfitting the cavity with side-mounted input coupler and beam line absorbers. We also discuss the production of six additional main-linac cavities as we progress toward constructing a full 6-cavity cryomodule.