Author: Meshkov, O.I.
Paper Title Page
MOPME064 SLM and Flags for Booster of NSLS-II 622
 
  • O.I. Meshkov, V. Smalyuk
    BINP SB RAS, Novosibirsk, Russia
  • V.L. Dorokhov
    BINP, Novosibirsk, Russia
 
  Set of diagnostics of booster of NSLS-II includes 6 fluorescent screens (flags) and 2 synchrotron light monitors (SLM). The flags will be applied during booster commissioning for closing of the beam turn. They are also a useful tool in case of malfunction elimination. SLM will be used both for booster comissioning and for operation. The details of calibration and design of the devices are discussed.  
 
TUPME028 RF Orbit Separation for CPT-Test Experiment at VEPP-4M 1634
 
  • V.E. Blinov, E.A. Bekhtenev, G.V. Karpov, V.A. Kiselev, S.A. Krutikhin, G.Y. Kurkin, E.B. Levichev, O.I. Meshkov, S.I. Mishnev, V.V. Neyfeld, S.A. Nikitin, I.B. Nikolaev, D.N. Shatilov, G.M. Tumaikin
    BINP SB RAS, Novosibirsk, Russia
  • A.P. Chabanov, O.P. Gordeev, A.I. Mickailov
    Budker INP & NSU, Novosibirsk, Russia
 
  Funding: This work was supported by the Ministry of Education and Science of the Russian federation and the Russian Foundation for Basis Research (grant 11-02-01422-a)
In a special program of experiments which is under development in a background regime at the VEPP-4M storage ring we set an aim to realize a potential possibility to make the CPT invariance test with the accuracy better than 10-8. The test will be based on a precise comparison of the spin precession frequencies of simultaneously stored electrons and positrons. To exclude the presence of static electric fields increasing a systematic error we have developed and tested a special RF system driven at the half revolution frequency to subsitute for the electrostatic orbit separation system. The latter is needed for the electron and positron orbit separation at the parasitic interaction point where the beam-beam effects drastically cut the beam currents.
 
 
TUPME029 VEPP-4: Application Beyond the High Energy Physics 1637
 
  • O.I. Meshkov
    BINP SB RAS, Novosibirsk, Russia
 
  The current status of VEPP-4M electron-positron collider has been described. During fall of 2011 the accelerator was shut down for planned reconstruction of KEDR detector. The next long run of the collider will be dedicated to the experiments at high energy physics within area of 2-5 GeV. Nevertheless, the set of experiments at booster VEPP-3 were continued. VEPP-3 was operated as an SR source, the experiment with internal target was performed and electron/positron scattering at proton was studied. The short runs of VEPP-4M were used as for commissioning of the new “warm” 3T wiggler as for experiments with an extracted electron beam dedicated for testing of different high energy physics detectors. The experiment of comparing of anomalous magnetic moment of electron and positron is con-tinued at VEPP-4M. The system of RF beam shifting is installed at a straight section of the accelerator. It is applied for elimination of parasitic interaction points of electron and positron beams. The first experiments with this system are described. KEDR detector reconstruction should be finished at autumn of 2013. The future experiments with KEDR detector are discussed.