MOPME043 Calibration of Beam Position Monitors in the Injector of HLS II 568
 
  • J.Y. Zou, J. Fang, W.B. Li, P. Lu, T.J. Ma, B.G. Sun, Y.L. Yang, Z.R. Zhou
    USTC/NSRL, Hefei, Anhui, People's Republic of China
 
  Funding: Supported by the National Science Foundation of China (11175173, 11105141)
A beam position monitor(BPM) system is being installed to improve the beam position measurement of the injector at the upgrade project of Hefei Light Source (HLS II). The new BPM system is consists of 19 stripline BPMs and 19 Libera Brilliance Single Pass modules. Before installation, the response of the BPMs must be mapped to improve the accuracy of measurement. The theoretical equations of both position and quadrupole component of the BPM are calculated first, using both formula and matlab simulation. A laboratory calibration system is built. The inconsistency of Libera Brilliance Single Pass channels is measured to improve the accuracy of calibration. The calibrating results show the position sensitivity is less than 5% difference compare to the theoretical value, while the quadrupole component sensitivity is less than 10% difference.