Author: Miyamoto, A.
Paper Title Page
MOPPP072 Performance of APPLE-II Type Quasi-Periodic Undulator at HiSOR 729
 
  • S. Sasaki, M. Arita, K. Goto, A. Miyamoto, T. Okuda
    HSRC, Higashi-Hiroshima, Japan
 
  A 1.8-m-long 78-mm-period quasi-periodic APLPE-II undulator was installed in the 700-MeV HiSOR storage ring of Hiroshima Synchrotron Radiation Center. At 23-mm nominal minimum gap, the fundamental photon energies are 3.1 eV, 6.5 eV, and 4.8 eV for horizontal linear, vertical linear, and circular polarization, respectively. The photon energies of observed fundamental and higher harmonic radiations are in good agreement with those of model calculations using measured undulator field and the HiSOR beam parameters. Also, observed flux thorough a slit and a grating monochromator was more than twice larger than that from previously installed 100-mm-period helical undulator for the whole range of radiation spectra. The feedforward COD correction was done to avoid the intensity fluctuation of photon beam in other BM beamlines due to the gap and phase motion of undulator. No fatal effect on the stored electron beam by installing the undulator was observed though a slight beam size change was observed at the minimum gap.  
 
TUPPP014 HiSOR-II, Compact Light Source with a Torus-knot Type Accumulator Ring 1635
 
  • A. Miyamoto, S. Sasaki
    HSRC, Higashi-Hiroshima, Japan
 
  Funding: This work is partially supported by Cooperative and Supporting Program for Researches and Educations in University sponsored by KEK.
We proposed a torus knot type synchrotron radiation ring where the beam orbit is not closed with one turn but return to the starting position after multiple turns around the ring. This ring is capable of having many straight sections and it is advantageous for installation of insertion devices. We named this architecture AMATELAS. We are designing a new ring based on the shape of a (11, 3) torus knot for our future plan HiSOR-II. This ring has eleven 3.6-m-long straight sections though the ring diameter is as compact as 15 m. The achieved emittance is 17.4 nmrad with the lattice having bending magnets with combined function. This level of emittance is as low as the conventional 3rd generation light source. On the other hand, there is a potential problem caused by that the radius of the orbit and focusing force are not constant in the bending magnets. However, we confirmed that it does not make serious influence to the beam by calculating with dividing the bending into several sections. We will compare the parameters of this new ring with the conventional ring which we have designed as the future plan of our facility and evaluate performance as the compact synchrotron light source.