MOPPR025 The BPM DAQ System Upgrade for SuperKEKB Injector Linac 834
 
  • M. Satoh, K. Furukawa, F. Miyahara, T. Suwada
    KEK, Ibaraki, Japan
  • T. Kudou, S. Kusano
    MELCO SC, Tsukuba, Japan
 
  The non-destructive beam position monitor (BPM) is indispensable diagnostic tool for the stable beam operation. In the KEK Linac, approximately nineteen BPMs with the strip-line type electrodes are used for the beam orbit measurement and feedback. In addition, some of them are also used for the beam energy feedback loops. The current DAQ system consists of the fast digital oscilloscopes. A signal from each electrode is analyzed with a predetermined response function up to 50 Hz. The beam position resolution of current system is limited to about 0.5 mm because of ADC resolution. Towards SuperKEKB project, we have a plan to upgrade the BPM DAQ system since the Linac should provide the smaller emittance beam. We will report the system description of the new DAQ system and the results of performance test in detail.  
 
TUPPR005 Linac Upgrade in Intensity and Emittance for SuperKEKB 1819
 
  • T. Higo, M. Akemoto, D.A. Arakawa, Y. Arakida, A. Enomoto, S. Fukuda, K. Furukawa, Y. Higashi, H. Honma, N. Iida, M. Ikeda, E. Kadokura, K. Kakihara, T. Kamitani, H. Katagiri, M. Kurashina, S. Matsumoto, T. Matsumoto, H. Matsushita, S. Michizono, K. Mikawa, T. Miura, F. Miyahara, T. Mori, H. Nakajima, K. Nakao, T. Natsui, Y. Ogawa, S. Ohsawa, M. Satoh, T. Shidara, A. Shirakawa, H. Sugimoto, T. Suwada, T. Takatomi, T. Takenaka, Y. Yano, K. Yokoyama, M. Yoshida, L. Zang, X. Zhou
    KEK, Ibaraki, Japan
  • D. Satoh
    TIT, Tokyo, Japan
 
  The SuperKEKB is designed to produce 40 times luminosity than that of the KEKB. In order to realize such a high luminosity, the injector linac should provide both electron and positron beams of about 4-5 nC/bunch, which is several times higher than before. In addition, their emittance requirement of the injection beam to the rings is 20 microns, which is a factor of a few tens smaller than before. The intensity and emittance of the electron beam are realized directly by developing the photo RF gun. In contrast, the positron intensity is increased by adopting a higher capture efficiency system with flux concentrator followed by large-aperture accelerators, while its emittance is reduced by a damping ring. For preserving such a low emittance of both beams toward the injection to the rings, the suppression of the emittance growth is crucial. To this end, the alignment of the accelerator components should be a few tens of microns, where we need an improvement by more than a factor 10. The beam-based alignment is definitely needed with better-resolution BPMs. In the present paper are reviewed the overall progress and perspective of the design and the associated component developments.