Author: Marqueta, A.
Paper Title Page
THPHA053 Status of the LIPAc MEBT Local Control System 1489
 
  • E. Molina Marinas, A. Guirao, L.M. Martinez Fresno, I. Podadera, V. Villamayor
    CIEMAT, Madrid, Spain
  • A. Marqueta
    IFMIF/EVEDA, Rokkasho, Japan
 
  Funding: This work has been partially supported by Spanish government (MINECO) in the frame of the BA Agreement Activities, and (MICINN) under project AIC-A-2011-0654 and FIS2013-40860-R
The Linear Ifmif Prototype Accelerator (LIPAc), is being commissioned in Rokkasho, Japan. The Medium Energy Beam Transport (MEBT) line has already been installed and connected to the ancillary systems, while the mechanical connections to the adjacent systems, the Radio Frequency Quadrupole (RFQ) and the Diagnostics Plate (DP), are under way. The status of the MEBT Local Control System (LCS) was presented in the previous edition of ICALEPCS [*]. Since then, the functional specifications of the MEBT components controls have been completed, the control cabinets have been designed and are now being installed and the software has been written. In this paper, the final architecture and functionality of the MEBT LCS will be described and the preliminary results of its commissioning will be presented.
[*]MEBT and D-Plate Control System Status of the Linear IFMIF Prototype Accelerator. J.Calvo et al. ICALEPCS 2015
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-ICALEPCS2017-THPHA053  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPHA157 IFMIF EVEDA RFQ Local Control System Integration into Main Control System 1771
 
  • M. Montis, L. Antoniazzi, A. Baldo, M.G. Giacchini
    INFN/LNL, Legnaro (PD), Italy
  • A. Jokinen
    F4E, Germany
  • A. Marqueta
    IFMIF/EVEDA, Rokkasho, Japan
 
  The RFQ apparatus Local Control System built for IFMIF EVEDA Project* has been designed and realized for being both a standalone architecture and part of a more complex control system composed by different sub-systems. This approach let RFQ's engineers and scientists have a degree of freedom during power tests in Legnaro and during the RFQ integration in IFMIF EVEDA facility in Rokkasho. In this paper we will describe the different aspects observed when the LCS was converted from the standalone configuration to the final integrated one.
* httpd://www.ifmif.org
 
poster icon Poster THPHA157 [3.961 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-ICALEPCS2017-THPHA157  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)