Paper |
Title |
Page |
TUPHA075 |
A MicroTCA based Beam Position Monitoring System at CRYRING@ESR |
585 |
|
- P.B. Miedzik, H. Bräuning, T. Hoffmann, A. Reiter, R. Singh
GSI, Darmstadt, Germany
|
|
|
At FAIR the commissioning of the re-assembled CRYRING accelerator, formerly hosted by Manne Siegbahn Laboratory Stockholm, is currently in progress. This compact low energy heavy ion synchrotron and experimental storage ring will be the main instrument for an extensive research programme [1] as well as a testing platform for the future beam instrumentation and control system concepts decided on for FAIR. Besides many other measurement systems CRYRING is equipped with 18 beam position monitors (BPM), for which a new data acquisition system (DAQ) was developed. Based on the upcoming MicroTCA form factor in combination with FPGA mezzanine card (FMC) technology the DAQ system was designed to be state-of-the-art, reliable, modular and of high performance. Testing 'Open Hardware', here the ADC FMCs and FMC carrier boards, was another intention of that concept. The DAQ layout and obstacles that had to be overcome as well as first measurements will be presented.
|
|
|
Poster TUPHA075 [18.571 MB]
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-ICALEPCS2017-TUPHA075
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|