TUPF06 Commissioning of the Electronics for HOM-based Beam Diagnostics at the 3.9 GHz Accelerating Module at FLASH 311
 
  • N. Baboi, O. Hensler, L. Shi, T. Wamsat
    DESY, Hamburg, Germany
  • N. Eddy, B.J. Fellenz
    Fermilab, Batavia, Illinois, USA
  • P. Zhang
    CERN, Geneva, Switzerland
 
  Funding: The work is part of EuCARD-2, partly funded by the European Commission, GA 312453.
Transverse Higher Order Modes (HOM) excited by electron beams in the 3.9 GHz accelerating cavities at FLASH may damage the beam quality. They can be reduced by extracting their energy through special couplers and by aligning the beam in the cavity. Electronics has been designed at FNAL for monitoring some of the potentially most damaging HOMs. This may be used for beam centering and therefore reducing the HOM effects. Moreover, the signals can be potentially calibrated into beam offset, so that they could be used as beam position monitors (HOM-BPM). The specifications of the monitors have been defined during an extensive study on the 4-cavity accelerating module installed at FLASH. Signals around 5.44 GHz have been chosen for higher precision measurements. However these signals propagate into the entire 1.2 m long module. Therefore in addition modes at about 9 GHz were selected for localized measurements in each cavity. The electronics has been recently installed at FLASH. The commissioning results will be presented in this paper. Instabilities previously observed in a test electronics as well as the HOM-BPMs in 1.3 GHz cavities will also be investigated*. This electronics will also serve as a prototype for the electronics developed for the 3.9 GHz cavities at the European XFEL**.
*L. Shi et al., this Conference
**T. Wamsat et al., this Conference
 
Export • reference for this paper to ※ LaTeX, ※ Text, ※ IS/RefMan, ※ EndNote (xml)  
 
TUPF10 Stability Study of the Higher Order Mode Beam Position Monitors at the Accelerating Cavities at FLASH 327
 
  • L. Shi, N. Baboi
    DESY, Hamburg, Germany
  • R.M. Jones
    UMAN, Manchester, United Kingdom
 
  When electron beams traverse an accelerating structure, higher order modes (HOMs) are excited. They can be used for beam diagnostic purposes. Both 1.3 GHz and 3.9 GHz superconducting accelerating cavities at FLASH linac, DESY, are equipped with electronics for beam position monitoring, which are based on HOM signals from special couplers. These monitors provide the beam position without additional vacuum components and at low cost. Moreover, they can be used to align the beam in the cavities to reduce the HOM effects on the beam. However, the HOMBPM (Higher Order Mode based Beam Position Monitor) shows an instability problem over time. In this paper, we will present the status of studies on this issue. Several methods are utilized to calibrate the HOMBPMs. These methods include DLR (Direct Linear Regression), and SVD (Singular Value Decomposition). We found that SVD generally is more suitable for HOMBPM calibration. We focus on the HOMBPMs at 1.3 GHz cavities. Techniques developed here are applicable to 3.9 GHz modules. The work will pave the way for HOMBPMs of the E-XFEL (European X-Ray Free Electron Laser).  
Export • reference for this paper to ※ LaTeX, ※ Text, ※ IS/RefMan, ※ EndNote (xml)