Paper |
Title |
Page |
MOIZB1 |
NSLS2 Diagnostic Systems Commissioning and Measurements |
16 |
|
- W.X. Cheng, B. Bacha, K. Ha, Y. Hu, M.A. Maggipinto, J. Mead, D. Padrazo, O. Singh, H. Xu
BNL, Upton, Long Island, New York, USA
|
|
|
As the newest and most advanced third generation light source, NSLS2 commissioning has started recently. A total of 50mA stored beam was achieved in the storage ring. Most of the diagnostic systems have been commissioned with beams and proved to be critical to the success of machine commissioning. This paper will present beam commissioning results of various diagnostic systems in the NSLS2 injector and storage ring, including profile monitors, current monitors, and position monitors. We will discuss some preliminary machine measurements as well, such as beam current and lifetime, tune, beam stability, filling pattern etc.
|
|
|
Slides MOIZB1 [6.187 MB]
|
|
Export • |
reference for this paper to
※ LaTeX,
※ Text,
※ IS/RefMan,
※ EndNote (xml)
|
|
|
MOPF03 |
NSLSII Photon Beam Position Monitor ElectronicsTesting and Results |
42 |
|
- A.J. Della Penna, M.A. Maggipinto, J. Mead, O. Singh, K. Vetter
BNL, Upton, Long Island, New York, USA
|
|
|
Simulated and real beam data has been taken using the new NSLSII Photon BPM electronics. The electrometer design can measure currents as low as 10’s of nanoamps and has an ability to measure a current as high as 300mA. The 4 channel design allows for internal calibration and has both a Negative and Positive bias ability. Preliminary bench testing results has shown excellent resolution.
|
|
Export • |
reference for this paper to
※ LaTeX,
※ Text,
※ IS/RefMan,
※ EndNote (xml)
|
|
|
TUPF01 |
NSLS-II RF Beam Position Monitor- System Test and Integration |
289 |
|
- D. Padrazo, A. Caracappa, W.X. Cheng, C. Danneil, A.J. Della Penna, K. Ha, M.A. Maggipinto, J. Mead, O. Singh, K. Vetter
BNL, Upton, Long Island, New York, USA
|
|
|
The NSLS-II Synchrotron Light Source is a 3 GeV electron storage ring currently in the early stages of commissioning at Brookhaven National Laboratory. The RF Beam Position Monitors (RF BPM) are one of the key diagnostics systems required for a successful and efficient commissioning. There are more than 250 RF BPM installed in the injector and the storage ring. Each RF BPM was fully tested, first under laboratory environment and then after installation, utilizing built in pilot tone signal source. These successful tests provided a solid base for the integrity of RF BPM systems, prior to the start of beam commissioning. This paper will describe tests performed and results of system integration.
|
|
|
Poster TUPF01 [1.068 MB]
|
|
Export • |
reference for this paper to
※ LaTeX,
※ Text,
※ IS/RefMan,
※ EndNote (xml)
|
|
|
WECYB2 |
NSLS-II RF Beam Position Monitor Comissioning Update |
500 |
|
- J. Mead, A. Caracappa, W.X. Cheng, C. Danneil, J.H. De Long, A.J. Della Penna, K. Ha, B.N. Kosciuk, M.A. Maggipinto, D. Padrazo, B. Podobedov, O. Singh, Y. Tian, K. Vetter
BNL, Upton, Long Island, New York, USA
|
|
|
The National Synchrotron Light Source II (NSLS-II) is a third generation light source currently in the commissioning stage at Brookhaven National Laboratory. The project includes a highly optimized, ultra-low emittance, 3GeV electron storage ring, linac pre-injector and full energy booster synchrotron. Successful commissioning of the booster began in November 2012, followed by the ongoing commissioning of the NSLS-II 3GeV electron storage ring which began in March 2014. With those particles first injected, came a value realization of the in-house developed RF Beam Position Monitor (RF BPM). This in-house design knowledge proved to be extremely valuable to match BPM configurations and requirements quickly when needed with various injected beam conditions. The RF BPM system was envisioned and undertaken to meet or exceed the demanding applications of a third generation light source. This internal R&D project has since matured to become a fully realized diagnostic system with over 250 modules currently operational. Initial BPM performance and applications will be discussed.
|
|
|
Slides WECYB2 [3.041 MB]
|
|