Keyword: status
Paper Title Other Keywords Page
MOPA09 Comparison of Three Different Concepts of High Dynamic Range and Dependability Optimised Current Measurement Digitisers for Beam Loss Systems radiation, monitoring, detector, operation 66
 
  • W. Viganò, B. Dehning, E. Effinger, G.G. Venturini, C. Zamantzas
    CERN, Geneva, Switzerland
 
  The first concept is based on current to frequency conversion, enhanced with an ADC for extending the dynamic range and decreasing the response time. A summary of 3 years worth of operational experience with such a system for LHC beam loss monitoring will be given. The second principle is based on an adaptive current to frequency converter implemented in an ASIC. The basic parameters of the circuit are discussed and compared with measurements. Several measures are taken to harden both circuits against single event effects and to make them tolerant for operation in radioactive environments. The third circuit is based on a fully differential integrator for enhanced dynamic range, where laboratory and test installation measurements will be presented. All circuits are designed to avoid any dead time in the acquisition and have reliability and fail safe operational considerations taken into account.