Author: Dölling, R.
Paper Title Page
MOP253 Progress with Bunch-shape Measurements at PSI's High-power Cyclotrons and Proton Beam Lines 187
 
  • R. Dölling
    PSI, Villigen PSI, Switzerland
 
  As proposed at HB2010, additional bunch-shape monitors have been installed at the last turns of the Injector 2 cyclotron and at several locations in the connecting beam line to the Ring cyclotron (@72 MeV), as well as behind the Ring cyclotron (@590 MeV). Now at each location in the beam lines, longitudinal-transversal 2D-density distributions of the bunched 2.2 mA proton beam can be taken from four angles of view, each separated by 45°. In addition the monitor in Injector 2 has been upgraded to observe the 13 outermost turns (@57 to 72 MeV), some of them from two or three angles of view. The measurement setup, data evaluation and results are outlined.  
 
FRO1B02 Qinclosing Plenary Summary of Working Group E:Diagnostics and Instrumentation for High-Intensity Beams 625
 
  • R. Dölling
    PSI, Villigen PSI, Switzerland
  • N. Hayashi
    JAEA/J-PARC, Tokai-Mura, Naka-Gun, Ibaraki-Ken, Japan
  • V.E. Scarpine
    Fermilab, Batavia, USA
 
  Working Group E Summary: Working group E was charged with presentations and discussions on diagnostics and instrumentation of high intensity beams. We had 2 sessions, consisting of a total of 12 talks, each of 20 minutes for presentation followed by some discussion. One session was followed by a discussion session of two hours. All sessions took place in parallel with the sessions of WG-D (Commissioning, operations and performance), inevitably preventing some possibly useful overlap. In addition, seven posters, regarding beam diagnostics, were presented in the single poster session.  
slides icon Slides FRO1B02 [18.507 MB]