MOP254 | Design of a Photo-detachment Emittance Instrument for FETS | 192 |
|
||
Photo detachment is a possibility to diagnose non-destructively H− ion beams. For emittance measurements, the produced neutrals are more suitable then the photo-detached electrons. Such a Photo-Detachment Emittance Measurement Instrument (PD-EMI) is planned for the Front End Test Stand (FETS) at Rutherford Appleton Laboratory (RAL/ UK). FETS comprises a Penning ion source of 60 mA beam current with up to 2 ms pulse length at 50pps, a Low Energy Beam Transport (LEBT), a four-vane RFQ with 3 MeV and a Medium Energy Beam Transport (MEBT) with a chopper system. The PD-EMI will be integrated at the end of the MEBT to commission the RFQ which is currently under construction. The introduction gives an overview some results reached so far and explains the conceptual design. Beam simulations show how to implement this to the MEBT being under construction. The remaining paper concentrates then on the hardware which is the dipole magnet, the laser and optics. The design and and engineering of the magnet chamber needs special attention to both satisfy beam transportation and diagnostics purpose. First measurements about the laser and its parameters will be presented. | ||