Keyword: beam-diagnostic
Paper Title Other Keywords Page
TUD02 Diffraction Radiation Monitor electron, radiation, target, diagnostics 561
 
  • Y. Taira
    AIST, Tsukuba, Japan
 
  Non-invasive beam diagnostics using a diffraction radiation (DR) has been developed at several electron accelerator facilities. Generation process of DR is similar to that of transition radiation (TR). TR is emitted when a charged particle passes through the boundary between two media with different dielectric constants. On the other hand, DR is emitted when it passes through in the vicinity of a boundary between two media. In the generation process of DR, the charged particle doesn't intersect the medium but its electric field intersects the medium. An aperture, a slit, and an edge are used for DR target. Optical wavelength of DR is usually used for beam diagnostics. One can evaluate energy, a transverse beam size, and a divergence of an electron beam by measuring a spatial distribution of DR. Moreover, coherent diffraction radiation with the wavelength of less than millimeter range is used for a bunch length measurement. In this conference, a theoretical background of DR and experimental results carried out at several facilities will be presented.  
Export • reference for this paper to ※ LaTeX, ※ Text, ※ IS/RefMan, ※ EndNote (xml)  
 
WEP042 Commissioning and First Performance of the LINAC-based Injector Applied in the HUST THz-FEL linac, FEL, target, gun 662
 
  • T. Hu, Q.S. Chen, J. Li, B. Qin, P. Tan, Y.Q. Xiong
    HUST, Wuhan, People's Republic of China
  • L. Cao, W. Chen
    Huazhong University of Science and Technology, State Key Laboratory of Advanced Electromagnetic Engineering and Technology,, Hubei, People's Republic of China
  • Y.J. Pei, Zh. X. Tang
    USTC/NSRL, Hefei, Anhui, People's Republic of China
 
  The construction of a compact high-power THz source based on the free electron laser(FEL), which is constructed in HUST, is undergoing. Before the end of 2014, we have installed most of the key components, completed conditioning of the LINAC-based FEL injector, and performed first beam experiment. During last 5 months, we have established a high efficient beam diagnostic system with a reliable online monitor platform and precise data processing methods. At present, longitudinal properties such as the micro-pulse width and the energy spread are kept to a reasonable level, while transverse emittance compensation by adjusting focusing parameters is still undergoing. In this paper, we will give the summary on the commissioning schedule, detailed commissioning plan, the development of the commissioning and first performance of the LINAC, etc.  
Export • reference for this paper to ※ LaTeX, ※ Text, ※ IS/RefMan, ※ EndNote (xml)