Author: Suh, Y.J.
Paper Title Page
TUP055 Technical Overview of Bunch Compressor System for PAL XFEL 490
 
  • H.-G. Lee, Y.-G. Jung, H.-S. Kang, D.E. Kim, K.W. Kim, S.B. Lee, D.H. Na, B.G. Oh, K.-H. Park, H.S. Suh, Y.J. Suh
    PAL, Pohang, Republic of Korea
 
  Pohang Accelerator Laboratory(PAL) is developing a SASE X-ray Free Electron Laser based on 10 GeV linear accelerator. Bunch compressor (BC) systems are developed to be used for the linear accelerator tunnel. It consists of three(BC1, BC2, BC3H) hard X-ray line and one(BC3S) soft X-ray line. BC systems are composed of four dipole magnets, three quadrupole magnet, BPM and collimator. The support system is based on an asymmetric four-dipole magnet chicane in which asymmetry and variable R56. can be optimized. This flexibility is achieved by allowing the middle two dipole magnets to move transversely. In this paper, we describe the design of the stages used for precise movement of the bunch compressor magnets and associated diagnostics components.  
Export • reference for this paper to ※ LaTeX, ※ Text, ※ IS/RefMan, ※ EndNote (xml)