TUPSO54 Undulators for Free Electron Lasers undulator, electron, focusing, insertion 351
 
  • C.W. Ostenfeld, M. Pedersen
    Danfysik A/S, Taastrup, Denmark
 
  Danfysik has produced insertion devices for the FEL community for almost 10 years. In this poster, we describe two recent undulator deliveries: a 2.8 m long undulator for the FELIX free electron laser, and a 4.5 m device for the FLARE project, both at Radboud University in Nijmegen, in the Netherlands. The device for FELIX is a 2.8 m PPM device, with a peak field of 0.483 T, and a minimum gap of 22 mm. The device for FLARE, is a 4.5 m hybrid device, with special poles, which allow for double focusing. For both devices, we describe the magnetic modelling, and the magnetic performance.  
 
TUPSO55 300 mm Electromagnetic Wiggler for ELBE wiggler, electron, insertion, vacuum 353
 
  • C.W. Ostenfeld, M. Pedersen
    Danfysik A/S, Taastrup, Denmark
 
  Danfysik has designed and built a 300 mm fixed-gap electromagnetic wiggler for the ELBE radiation source at Helmholz Zentrum Dresden Rossendorff. This wiggler will serve as a source of narrow-band THz radiation in the 100 μm to 10 mm range. Due to careful magnetic modelling, and an effective shimming process, we were able to deliver magnetic performance at a high level. We present the details of the modelling, as well as magnetic results.