A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Cutic, N.     [Čutić, N.]

Paper Title Page
WEOA4 First Results of Coherent Harmonic Generation at the MAX-Lab Test Fel 340
 
  • S. Werin, N. Čutić, F. Lindau, S. Thorin
    MAX-lab, Lund
  • J. Bahrdt, K. Holldack
    HZB, Berlin
  • C. Erny, A. L'Huillier, E. Mansten
    Lund University, Division of Atomic Physics, Lund
 
 

The first generation of coherent harmonic radiation from the MAX-lab test FEL have recently been achieved. The 380 MeV electron beam has been seeded by a 263 nm Ti:Sapphire laser and coherent radiation in the harmonics 1 to 4 (263 – 66 nm) has been produced both in linear and circular polarization mode. The facility consists of a photo cathode RF gun, the MAX injector (two 95 MeV linacs placed in a recirculator), beam transport including compression optics and the two undulators (modulator and radiator) separated by a four magnet chicane for bunching control. The radiator undulator is of Apple type providing tunable polarization. The basic characterization of the source with dynamic studies of laser energy, undulator gap and chicane influence on the coherent harmonic signal will be reported.

 

slides icon

Slides

 
WEPA11 The MAX IV Injector as a Soft X-Ray FEL Driver 382
 
  • S. Werin, N. Čutić, M. Eriksson, F. Lindau, S. Thorin
    MAX-lab, Lund
 
 

The MAX IV injector is funded and under construction. It is designed to drive a Short Pulse Facility generating spontaneous incoherent photon pulses in the keV range with pulse lengths below 100 fs in the first phase of the project. This source will with minor modifications be able to drive a Free Electron Laser down into the soft X-ray region and with an extended energy a full X-ray FEL at 1-2 Å. The key feature of the system is the availability of a 3-3.5 GeV linac, a low emittance photo cathode RF-gun and two bunch compressors including sextupoles for linearization. By extracting pulses of 0.1-0.2 nC charge, normalized emittances below 1 mm mRad and peak currents above 3 kA can be achieved. Such pulses are very well suited for a FEL facility. We describe the MAX IV injector system and discuss the options and perspectives for an X-ray FEL at the MAX IV facility.

 
THOA4 On-Line Arrival Time and Jitter Measurements Using Electro-Optical Spectral Decoding 548
 
  • N. Čutić, F. Lindau, S. Werin
    MAX-lab, Lund
  • E. Mansten
    Lund University, Division of Atomic Physics, Lund
 
 

Electro-optical spectral decoding was used to on-line monitor the arrival time of the electron bunches relative to the seed laser pulse at the test FEL facility at MAX-lab. An infrared chirped pulse coming from the seed laser is influenced by an electron bunch induced birefringence in a ZnTe birefringent crystal and the arrival time is determined from its spectrum. The possibility of running simultaneously with the FEL allowed for a feedback scheme to be built to compensate for the long term drifts in the system. Also, the whole system (the accelerator and the lasers) were synchronized to the power grid frequency. This lock increased the stability and was monitored by the EO setup. Measurements of the bunch length were performed and their correlation with arrival time pointed towards main contributors to the jitter in the system.

 

slides icon

Slides