Author: Padrazo Jr, D.
Paper Title Page
TUPLM36 Temperature Measurements of the NSLS-II Vacuum Components 443
 
  • A. Blednykh, G. Bassi, C. Hetzel, B.N. Kosciuk, D. Padrazo Jr, T.V. Shaftan, V.V. Smaluk, G.M. Wang
    BNL, Upton, New York, USA
 
  This paper is dedicated to the analysis of our recent experience from ramp-up of operating current at NSLS-II from 25 mA at the end of commissioning in 2014 to 475 mA achieved in studies today. To approach the design level of the ring intensity we had to solve major problems in overheating of the chamber components. Since the beginning of the NSLS-II commissioning, the temperature of the vacuum components has been monitored by the Resistance Temperature Detectors located predominantly outside of the vacuum chamber and attached to the chamber body. A couple of vacuum components were designed with the possibility for internal temperature measurements under the vacuum as diagnostic assemblies. Temperature map helps us to control overheating of the vacuum components around the ring especially during the current ramp-up. The average current of 475mA has been achieved with two main 500MHz RF cavities and w/o any harmonic cavities. In this paper we discuss the heating results for a 15ps bunch length (at low current) of the following vacuum components: Large Aperture BPM, Small Aperture BPM, Bellows, Flanges, Ceramics Chambers and Stripline Kickers.  
poster icon Poster TUPLM36 [3.696 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-NAPAC2019-TUPLM36  
About • paper received ※ 28 August 2019       paper accepted ※ 05 September 2019       issue date ※ 08 October 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)