Author: Mustapha, B.
Paper Title Page
MOOHC2 The US Electron Ion Collider Accelerator Designs 1
 
  • A. Seryi, S.V. Benson, S.A. Bogacz, P.D. Brindza, M.W. Bruker, A. Camsonne, E. Daly, P. Degtiarenko, Y.S. Derbenev, M. Diefenthaler, J. Dolbeck, R. Ent, R. Fair, D. Fazenbaker, Y. Furletova, B.R. Gamage, D. Gaskell, R.L. Geng, P. Ghoshal, J.M. Grames, J. Guo, F.E. Hannon, L. Harwood, S. Henderson, H. Huang, A. Hutton, K. Jordan, D.H. Kashy, A.J. Kimber, G.A. Krafft, R. Lassiter, R. Li, F. Lin, M.A. Mamun, F. Marhauser, R. McKeown, T.J. Michalski, V.S. Morozov, P. Nadel-Turonski, E.A. Nissen, G.-T. Park, H. Park, M. Poelker, T. Powers, R. Rajput-Ghoshal, R.A. Rimmer, Y. Roblin, D. Romanov, P. Rossi, T. Satogata, M.F. Spata, R. Suleiman, A.V. Sy, C. Tennant, H. Wang, S. Wang, C. Weiss, M. Wiseman, W. Wittmer, R. Yoshida, H. Zhang, S. Zhang, Y. Zhang, Z.W. Zhao
    JLab, Newport News, Virginia, USA
  • D.T. Abell, D.L. Bruhwiler, I.V. Pogorelov
    RadiaSoft LLC, Boulder, Colorado, USA
  • E.C. Aschenauer, G. Bassi, J. Beebe-Wang, J.S. Berg, M. Blaskiewicz, A. Blednykh, J.M. Brennan, S.J. Brooks, K.A. Brown, K.A. Drees, A.V. Fedotov, W. Fischer, D.M. Gassner, W. Guo, Y. Hao, A. Hershcovitch, H. Huang, W.A. Jackson, J. Kewisch, A. Kiselev, V. Litvinenko, C. Liu, H. Lovelace III, Y. Luo, F. Méot, M.G. Minty, C. Montag, R.B. Palmer, B. Parker, S. Peggs, V. Ptitsyn, V.H. Ranjbar, G. Robert-Demolaize, T. Roser, S. Seletskiy, V.V. Smaluk, K.S. Smith, S. Tepikian, P. Thieberger, D. Trbojevic, N. Tsoupas, E. Wang, W.-T. Weng, F.J. Willeke, H. Witte, Q. Wu, W. Xu, A. Zaltsman, W. Zhang
    BNL, Upton, New York, USA
  • D.P. Barber
    DESY, Hamburg, Germany
  • I.V. Bazarov
    Cornell University, Ithaca, New York, USA
  • G.I. Bell, J.R. Cary
    Tech-X, Boulder, Colorado, USA
  • Y. Cai, Y.M. Nosochkov, A. Novokhatski, G. Stupakov, M.K. Sullivan, C.-Y. Tsai
    SLAC, Menlo Park, California, USA
  • Z.A. Conway, M.P. Kelly, B. Mustapha, U. Wienands, A. Zholents
    ANL, Lemont, Illinois, USA
  • S.U. De Silva, J.R. Delayen, H. Huang, C. Hyde, S. Sosa, B. Terzić
    ODU, Norfolk, Virginia, USA
  • K.E. Deitrick, G.H. Hoffstaetter
    Cornell University (CLASSE), Cornell Laboratory for Accelerator-Based Sciences and Education, Ithaca, New York, USA
  • D. Douglas
    Douglas Consulting, York, Virginia, USA
  • V.G. Dudnikov, R.P. Johnson
    Muons, Inc, Illinois, USA
  • B. Erdelyi, P. Piot
    Northern Illinois University, DeKalb, Illinois, USA
  • J.D. Fox
    Stanford University, Stanford, California, USA
  • J. Gerity, T.L. Mann, P.M. McIntyre, N. Pogue, A. Sattarov
    Texas A&M University, College Station, USA
  • E. Gianfelice-Wendt, S. Nagaitsev
    Fermilab, Batavia, Illinois, USA
  • Y. Hao, P.N. Ostroumov, A.S. Plastun, R.C. York
    FRIB, East Lansing, Michigan, USA
  • T. Mastoridis
    CalPoly, San Luis Obispo, California, USA
  • J.D. Maxwell, R. Milner, M. Musgrave
    MIT, Cambridge, Massachusetts, USA
  • J. Qiang, G.L. Sabbi
    LBNL, Berkeley, California, USA
  • D. Teytelman
    Dimtel, Redwood City, California, USA
  • R.C. York
    NSCL, East Lansing, Michigan, USA
 
  With the completion of the National Academies of Sciences Assessment of a US Electron-Ion Collider, the prospects for construction of such a facility have taken a step forward. This paper provides an overview of the two site-specific EIC designs: JLEIC (Jefferson Lab) and eRHIC (BNL) as well as brief overview of ongoing EIC R&D.  
slides icon Slides MOOHC2 [14.774 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-NAPAC2019-MOOHC2  
About • paper received ※ 29 August 2019       paper accepted ※ 04 September 2019       issue date ※ 08 October 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPLO15 Engineering and Fabrication of the High Gradient Structure for Compact Ion Therapy Linac 267
 
  • O. Chimalpopoca, R.B. Agustsson, S.V. Kutsaev, A.Yu. Smirnov, A. Verma
    RadiaBeam, Santa Monica, California, USA
  • A. Barcikowski, R.L. Fischer, B. Mustapha
    ANL, Lemont, Illinois, USA
 
  RadiaBeam is fabricating a novel ultra-high gradient linear accelerator for the Advanced Compact Carbon Ion LINAC (ACCIL) project. The ACCIL is an Argonne National Laboratory (ANL) led project, in collaboration with RadiaBeam, designed to be capable of delivering sufficiently energized carbon ions and protons while maintaining a 50 m footprint. This is made possible by the development of S-Band 50 MV/m accelerating structures for particles with beta of 0.3 or higher. Such high gradient accelerating structures require particular care in their engineering details and fabrication process to limit the RF breakdown at the operating gradients. The details of fabrication and engineering design of the accelerating structure will be presented.  
poster icon Poster MOPLO15 [1.050 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-NAPAC2019-MOPLO15  
About • paper received ※ 28 August 2019       paper accepted ※ 12 September 2019       issue date ※ 08 October 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUZBA3 A High-Energy Design for JLEIC Ion Complex 341
 
  • B. Mustapha, J.L. Martinez Marin
    ANL, Lemont, Illinois, USA
  • Y.S. Derbenev, F. Lin, V.S. Morozov, Y. Zhang
    JLab, Newport News, Virginia, USA
 
  Funding: This work was supported by the U.S. DOE under Contract No. DE-AC02-06CH11357 for ANL and by Jefferson Science Associates, LLC under U.S. DOE Contract No. DE-AC05-06OR23177 and DE-AC02-06CH11357.
A recent assessment of the scientific merit for a future Electron Ion Collider (EIC) in the US, by the National Academy of Sciences, found that such a facility would be unique in the world and would answer science questions that are compelling, fundamental, and timely. This assessment confirmed the recommendations of the 2015 Nuclear Science Advisory Committee for an EIC with highly polarized beams of electrons and ions, sufficiently high luminosity and variable center-of-mass (CM) energy. The baseline design of Jefferson Lab Electron-Ion Collider (JLEIC) has been updated to 100 GeV CM energy, corresponding to 200 GeV proton energy. We here present a high-energy design for the JLEIC ion complex. It consists of a 135 MeV injector linac, a 6-GeV non figure-8 pre-booster ring and a 40-GeV large ion booster, which could also serve as electron storage ring (e-ring). The energy choice in the accelerator chain is beneficial for a future upgrade to 140 GeV CM energy. The large booster is designed with the same shape and size of the original e-ring allowing for the option of building separate electron and ion rings by stacking them in the same tunnel along with the ion collider ring.
 
slides icon Slides TUZBA3 [5.435 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-NAPAC2019-TUZBA3  
About • paper received ※ 03 September 2019       paper accepted ※ 25 November 2019       issue date ※ 08 October 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPLO01 Dual-Function Electron Ring-Ion Booster Design for JLEIC High-Energy Option 529
SUPLH10   use link to see paper's listing under its alternate paper code  
 
  • J.L. Martinez Marin, B. Mustapha
    ANL, Lemont, Illinois, USA
  • L.K. Spentzouris
    Illinois Institute of Technology, Chicago, Illinois, USA
 
  Funding: This work was supported by the U.S. DOE, Office of Nuclear Physics, under Contract No. DE-AC02-06CH11357 for ANL and by Jefferson Science Associates, LLC under U.S. DOE Contract No. DE-AC05-06OR23177.
As part of the alternative design approach for the Jeffer-son Laboratory Electron-Ion Collider (JLEIC) ion com-plex, the electron storage ring (e-ring) is consolidated to also serve as a large booster for the ions. The goal of reaching 16 GeV/u or higher for all ions using only room-temperature magnets forces the re-design of the e-ring because of magnetic field and lattice limitations. The new design is challenging due to several imposed constraints: (1) use of room-temperature magnets, (2) avoiding transi-tion crossing, and (3) maintaining the size and shape of the original e-ring design as much as possible. A design study is presented for a 16 GeV/u large ion booster after analyzing different alternatives that use: (1) combined-function magnets, (2) large quadrupoles or (3) quadrupole doublets in the lattice design. This design boosts the injection energy to the collider ring from 8 GeV (proton-equivalent) in the original baseline design to 16 GeV/u for all ions which is beneficial for the high-energy option of JLEIC of 200 GeV or higher. A scheme for adapting the new large ion booster design to also serve as electron storage ring is presented.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-NAPAC2019-TUPLO01  
About • paper received ※ 28 August 2019       paper accepted ※ 05 September 2019       issue date ※ 08 October 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPLO02 Spin Dynamics in the JLEIC Ion Injector Linac 533
SUPLH11   use link to see paper's listing under its alternate paper code  
 
  • J.L. Martinez Marin, B. Mustapha
    ANL, Lemont, Illinois, USA
  • L.K. Spentzouris
    Illinois Institute of Technology, Chicago, Illinois, USA
 
  Funding: This work was supported by the U.S. DOE, Office of Nuclear Physics, under Contract No. DE-AC02-06CH11357 for ANL and by Jefferson Science Associates, LLC under U.S. DOE Contract No. DE-AC05-06OR23177.
One of the requirements for the future Electron Ion Col-lider (EIC) is to collide polarized electrons and light ions with at least 70% polarization for each beam. For light ions, polarized ion sources are used for injection to a linac, which is usually the first accelerator in the collider chain. The Jefferson Lab EIC (JLEIC) ion injector linac consists of a low-energy room-temperature section with quadrupole focusing followed by a superconducting linac with solenoid focusing inside long cryomodules. These two sections have different effects on the spin. Spin dy-namics simulation studies are carried out for the JLEIC injector linac in order to preserve and maintain a high degree of polarization for light ion beams for delivery to the booster. The different options to maintain and restore the spin in the different sections of the linac for hydrogen, deuterium and helium ions are presented and discussed. Results from both the Zgoubi and COSY-Infinity codes are presented and compared for every section of the ion linac but the radio-frequency quadrupole (RFQ). Current-ly, a method to simulate the RFQ using Zgoubi is being investigated.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-NAPAC2019-TUPLO02  
About • paper received ※ 28 August 2019       paper accepted ※ 19 November 2019       issue date ※ 08 October 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPLM72 Design of a High-Gradient S-Band Annular Coupled Structure 762
 
  • B. Mustapha, A. Abogoda, A. Barcikowski, R.L. Fischer, A. Nassiri
    ANL, Lemont, Illinois, USA
 
  Funding: This work was supported by the U.S. DOE under Contract No. DE-AC02-06CH11357 through ANL’s LDRD program.
At Argonne, we have recently developed a conceptual design for a compact linear accelerator for ion beam therapy named ACCIL [1]. A linac-based ion-beam therapy facility offers many advantages over existing synchrotron based facilities. In addition to the reduced footprint, ACCIL offers more flexibility in beam tuning, including pulse-per-pulse energy and intensity modulation and fast switching between ion species. Essential to the compactness of the ACCIL linac are high-gradient structures for low to intermediate velocity ions, capable of accelerating fields of ~ 50 MV/m. For this purpose, we have designed an S-band annular-coupled structure (ACS). An ACS has the desired qualities of high electric field limit, high shunt-impedance, large area for magnetic coupling and good cooling capacity, making it a very promising candidate for high-gradient operations. We here present the optimized RF design for a β ~ 0.4 ACS.
* P. Ostroumov, et al., "Compact Carbon Ion Linac", Proceedings of NAPAC2016, Oct 10-14 2016, Chicago, IL
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-NAPAC2019-WEPLM72  
About • paper received ※ 04 October 2019       paper accepted ※ 16 November 2020       issue date ※ 08 October 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)