MOPMK017 | Transient Beam Loading Due to the Bunch Train Gap and Its Compensation Experiments at BEPC-II and ALS | 390 |
|
||
Funding: Authored by Jefferson Science Associates, LLC under U.S. DOE Contract No. DE-AC05-06OR23177. Non-uniform bunch fill patterns in storage rings, driven by the need to provide gaps for beam aborting and ion clearing cause a large beam loading change in the RF cavities. The induced turn-periodic transient in the cavity voltage modulates longitudinal beam properties along the train, such as synchronous position and bunch length. In the EIC design, due to the asymmetric bunch train structure between the electron and the ion beam, such modulation results in shifting collision point and leads to reduced luminosity. We have carried out the beam based experiments at BEPC-II and ALS using bunch-by-bunch diagnostic capabilities of the coupled-bunch feedback systems to study this transient effect. A modulated bunch filling pattern with higher charge density around the gap has been demonstrated to be effective in partially compensating this transient modulation. Details of the experimental setups and the data analysis will be presented to this conference. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-MOPMK017 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
WEPAL005 | Beam Size Measurement and PSF Evaluate of KB Mirror Monitor at SSRF | 2151 |
|
||
Funding: Work supported by National Nature Science Foundation of China(11605213) A Kirkpatrick Baez mirror imaging system was designed and installed to measure the transverse beam size and emittance of SSRF storage ring. Two crossed cylindrical mirrors are used to image the dipole source point in the horizontal and vertical direction. Both mirrors could be moved in and out in order to interchangeable with an original X-ray pinhole system. Hard X-ray with peak energy of 20.5 keV was focused at the X-ray scintillator camera. Aberration and point spread function which would cause image blur were evaluated. System commissioning and optimization have been done. PSF measurement was acquired using beam based calibration scheme by varying the beam images with different quadrupole settings and fitting them with the corresponding theoretical beam sizes. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-WEPAL005 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |