Author: Yang, Y.C.
Paper Title Page
WEPAL063 A Method to Tune Pulse Magnets' Waveforms 2320
 
  • T.Y. Lee, B.Y. Chen, S. Fann, C.S. Huang, C.H. Kuo, C.C. Liang, W.Y. Lin, Y.-C. Liu, Y.C. Yang
    NSRRC, Hsinchu, Taiwan
 
  Pulse magnets are used in storage ring injection kickers. The waveform of the the four kickers have strong relation with injection efficiency. A slightly offset of waveform may cause the four kickers mismatched, which would lead to storaged beam loss and decrease injection efficiency. In order to define the peak value and timing of the half-sine waveform which has noises interfering diagnosis, a curve-fitting method was introduced to monitor and fine-tuning the waveform. The waveforms' data are also archived for reference in case of replacing power supplies. By using this method, it helps to retain a consistent injection efficiency after the power supplies maintenance or replacement.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-WEPAL063  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPAL064 Diagnosis Application by Great Amount Operation Data Analysis Program for Taiwan Photon Source 2323
 
  • C.C. Liang, B.Y. Chen, C.H. Chen, S. Fann, C.S. Huang, C.H. Kuo, T.Y. Lee, W.Y. Lin, Z.-D. Tsai, Y.C. Yang, T.-C. Yu
    NSRRC, Hsinchu, Taiwan
 
  To find out abnormal situations of the machine for preventive maintenance or machine trip tracking or instability source diagnosis, a large amount of operating data in an accelerator is thus can be used to build a series data analysis program. When the archived data is classified accordingly, the standard deviation (STD), peak-to-peak value and other statistic indexes within the inspection time zone by the belonging families can be used to point out the especially abnormal signals. The analysis program adopts the techniques of parallel calculation and memory optimization to greatly reduce the time for data transmission and analysis and also displays the correlation signals to opera-tors for deeper analysis. This paper illustrated a simple yet effective method for quickly identifying a not-so-obscure hardware issue by simply using a personal computer (PC).  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-WEPAL064  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPAL056 Vibration Measurements in the TPS Vacuum System 3772
 
  • Y.C. Yang, C.K. Chan, C.-C. Chang, C.S. Chen, J. -Y. Chuang, Y.M. Hsiao, C.C. Liang, Y.Z. Lin
    NSRRC, Hsinchu, Taiwan
 
  The Taiwan Photon Source (TPS) is currently operated in top-up mode for users. In order to improve the stability of the synchrotron light source, vibrations related to the vacuum system have been investigated and improved by turning off pumping systems and reducing the flow rate in chamber cooling water circuits. In this paper, vibrations in different vacuum chambers with normal cooling water condition were investigated, their sources were recorded and clarified and properties of different materials for water tubes were also compared.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-THPAL056  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPAL057 Development of the Aluminum Beam Duct for the Ultra-Low Emittance Light Source 3775
 
  • G.-Y. Hsiung, J.-R. Chen, C.M. Cheng, S-N. Hsu, H.P. Hsueh, Y.C. Yang
    NSRRC, Hsinchu, Taiwan
  • J.-R. Chen
    National Tsing Hua University, Hsinchu, Taiwan
 
  The future light source with ultra-low emittance, typically < 500 pm rad, requests the beam duct with inner aperture < 20 mm for the electron storage ring. Besides, the cross section of the beam duct must be kept smooth for lowering the impedance. The aluminum extruded beam duct of 10 mm inside and 1 ~ 2 m in length was developed for this purpose. The beam duct was machined in ethanol to obtain a clean surface for a lower thermal outgassing rate. To mitigate the impedance of the flange connection, a special designed diamond-edge gasket and the aluminum flange without knife edge were developed. The inner diameters of both flange and gasket, 10 mm, are the same as that of beam duct. The sealing of the gasket has been proved leak-tight. The ultimate pressure and the thermal outgassing rate of the beam duct has achieved < 2.0·10-10 Torr and < 1.4·10-13 Torr l/(s cm2), respectively after baking. Those results fulfill both the ultrahigh vacuum and lowest impedance are applicable for the next generation ultra-low emittance light source.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-THPAL057  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPAL058 Effect of Ozonated Water Cleaning on Photon Stimulated Desorption in a Stainless Steel Chamber 3778
 
  • C.M. Cheng, C.K. Chan, C.-C. Chang, Y.T. Cheng, J. -Y. Chuang, G.-Y. Hsiung, L.H. Wu, Y.C. Yang
    NSRRC, Hsinchu, Taiwan
 
  Aluminium vacuum chambers cleaned with ozonated water show a reduction of residual carbon and lower surface outgassing rate after baking. We would like to investigate if stainless steel chambers show similar ef-fects. A stainless steel test chamber was cleaned by stand-ard chemical cleaning only and then compared with an-other one after immersion in 30ppm ozonated water for thirty minutes. Both samples were baked, then photon exposed and the photon desorption yields were deter-mined by vacuum gauges and residual gas analysers at the TLS 19B beamline. The test results on photon stimulated desorption yields and partial pressure variations with and without ozonated water cleaning of the stainless steel tubes will be discussed in some detail.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-THPAL058  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPAL059 TEMPERATURE ISSUES OF THE TPS BPMS 3781
 
  • Y.T. Huang, C.-C. Chang, C.M. Cheng, P.J. Chou, Y.C. Yang
    NSRRC, Hsinchu, Taiwan
 
  Since the TPS is capable to operate at higher currents, long-term 400mA conditioning runs were conducted. Current-dependent temperature data of BPMs were collected and analysed for both, aluminium and stainless steel BPM chambers. To better understand beam coupling effects in different types of TPS BPMs, electromagnetic and thermal simulation models were established. In this paper, we discuss associated results of such studies.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-THPAL059  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)