Paper |
Title |
Page |
TUPAL017 |
Performance and Status of the J-PARC Accelerators |
1038 |
|
- K. Hasegawa, N. Hayashi, M. Kinsho, H. Oguri, K. Yamamoto, Y. Yamazaki
JAEA/J-PARC, Tokai-Mura, Naka-Gun, Ibaraki-Ken, Japan
- T. Koseki, F. Naito, M. Yoshii
KEK, Tokai, Ibaraki, Japan
- N. Yamamoto
J-PARC, KEK & JAEA, Ibaraki-ken, Japan
|
|
|
The J-PARC is a high intensity proton facility and the accelerator consists of a 400 MeV linac, a 3 GeV Rapid Cycling Synchrotron (RCS) and a 30 GeV Main Ring Synchrotron (MR). Regarding 3 GeV beam from the RCS, we delivered it at 150 kW to the materials and life science experimental facility (MLF), for the neutron and muon users. The beam powers for the neutrino experiment at 30 GeV was 420 kW in May 2016, but increased to 470 kW in February 2017 thanks to the change and optimization of operation parameters. For the hadron experimental facility which uses a slow beam extraction mode at 30 GeV, we delivered beam at a power of 37 kW, after the recovery from a trouble at an electro static septum. We have experienced many failures and troubles to impede full potential and high availability. In this report, operational performance and status of the J-PARC accelerators are presented.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2018-TUPAL017
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
WEPAL022 |
Operating Experience of Water Cooling System in the J-PARC LINAC and RCS |
2203 |
|
- K. Suganuma, K. Fujirai, M. Kinsho, P.K. Saha, Y. Yamazaki
JAEA/J-PARC, Tokai-Mura, Naka-Gun, Ibaraki-Ken, Japan
|
|
|
The cooling system for the J-PARC LINAC and RCS uses a total of 25 circulation pumps to cool the accelerator devices. In February 2017, we experienced damage of circulation pumps due to low flow rate, and started the development of an abnormality detection system concentrating on the vibration measurements of the circulation pumps. In this report, the vibration measurement results of the coolant circulation pumps and the development status of abnormality detection through multivariate analysis using vibration values are discussed.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2018-WEPAL022
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|