Author: Shen, X.
Paper Title Page
TUPMF039 Recommissioning of the Canadian Light Source Booster Synchrotron 1338
 
  • W.A. Wurtz, D. Bertwistle, L.O. Dallin, X. Shen, J.M. Vogt
    CLS, Saskatoon, Saskatchewan, Canada
 
  The Canadian Light Source booster synchrotron was originally commissioned in 2002 and has worked reliably for many years. However, the operating point was not the design operating point and the booster suffered from poor quantum lifetime at the extraction energy. The low quantum lifetime caused current loss of approximately 25% in the microseconds before extraction. We have recommissioned the booster using the design optics, and the current loss before extraction is now only 6%. In this paper, we discuss the measurements and simulations involved in our recommissioning work.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-TUPMF039  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)