Paper |
Title |
Page |
MOPML043 |
High Gradient Performance of an S-Band Backward Traveling Wave Accelerating Structure for Medical Hadron Therapy Accelerators |
491 |
SUSPL097 |
|
|
- A. Vnuchenko, C. Blanch Gutiérrez, D. Esperante Pereira
IFIC, Valencia, Spain
- S. Benedetti, N. Catalán Lasheras, A. Grudiev, B. Koubek, G. McMonagle, I. Syratchev, B.J. Woolley, W. Wuensch
CERN, Geneva, Switzerland
- A. Faus-Golfe
LAL, Orsay, France
- T.G. Lucas, M. Volpi
The University of Melbourne, Melbourne, Victoria, Australia
- S. Pitman
Cockcroft Institute, Lancaster University, Lancaster, United Kingdom
|
|
|
The high-gradient performance of an accelerating structure prototype for a medical proton linac is presented. The structure was designed and built using technology developed by the CLIC collaboration and the target application is the TULIP (Turning Linac for Proton therapy) proposal developed by the TERA foundation. The special feature of this design is to produce gradient of more than 50 MV /m in low-β accelerating structures (v/c=0.38). The structure was tested in an S-band test stand at CERN. During the tests, the structure reached over above 60 MV/m at 1.2 μs pulse length and breakdown rate of about 5x10-6 bpp. The results presented include ultimate performance, long term behaviour and measurements that can guide future optimization.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2018-MOPML043
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
WEPMF074 |
High Power Conditioning of X-Band RF Components |
2545 |
|
- N. Catalán Lasheras, H. Damerau, R.L. Gerard, A. Grudiev, G. McMonagle, J. Paszkiewicz, A. Solodko, I. Syratchev, B.J. Woolley, W. Wuensch, V. del Pozo Romano
CERN, Geneva, Switzerland
- T.G. Lucas, M. Volpi
The University of Melbourne, Melbourne, Victoria, Australia
- S. Pitman
Lancaster University, Lancaster, United Kingdom
- A. Vnuchenko
IFIC, Valencia, Spain
|
|
|
As part of the effort to qualify CLIC accelerating struc-tures prototypes, new X-band test facilities have been built and commissioned at CERN in the last years. In this context, a number of RF components have been designed and manufactured aiming at stable operation above 50 MW peak power and several kW of average power. All of them have been tested now in the X-band facility at CERN either as part of the facility or in dedicated tests. Here, we describe shortly the main design and manufac-turing steps for each component, the testing and eventual conditioning as well as the final performance they achieved.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2018-WEPMF074
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|