Paper |
Title |
Page |
TUPMF084 |
Optimization of the Injection Kicker Bump Leakage at PETRA III |
1467 |
|
- J. Keil, G. Kube, F. Obier, G.K. Sahoo, R. Wanzenberg
DESY, Hamburg, Germany
|
|
|
PETRA III is a third generation synchrotron light source at DESY delivering high brightness photon beams for users at 21 beam lines. It is operated at 6 GeV with a beam current of 100 mA in top-up mode and is in operation for users since 2010. An off-axis injection scheme is used to accumulate beam from the booster synchrotron DESY II in PETRA III. Three fast injection kicker magnets generate a closed orbit bump for one turn to move the stored beam near to the injection septum magnet. Ideally the orbit bump generated by the 10 μs long half-sine pulses of the kickers should be closed. Due to differences in pulse shape as well as timing and amplitude errors of the pulses there is some leakage of the injection bump which disturbs the closed orbit and affects the beam quality during top-up operation. Turn-by-turn data from the beam position monitor (BPM) system of PETRA III have been used to measure the bump leakage for different bucket positions in the filling pattern. The procedure to reduce the injection kicker bump leakage and the achieved improvement will be discussed.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2018-TUPMF084
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|