Paper | Title | Page |
---|---|---|
TUYGBE3 | Recent progress of short pulse dielectric two-beam acceleration | 640 |
|
||
Two-Beam Acceleration (TBA) is a structure-based wakefield acceleration method with the potential to meet the luminosity and cost requirements of a TeV class linear collider. The Argonne Wakefield Accelerator (AWA) facility is developing a dielectric-based short pulse TBA scheme with the potential to withstand high acceleration gradients and to achieve low fabrication cost. Recently, the dielectric short pulse TBA technology was successfully demonstrated using K-band 26 GHz structures, achieving 55 MW output power from the power extractor and 28 MeV/m gradient in the accelerator. To improve the generated rf power, an X-band 11.7 GHz power extractor has been developed, which obtained 105 MW in the high power test. In addition, a novel dielectric disk accelerator (DDA) is currently under investigation to significantly increase the efficiency of linear colliders based on short pulse TBA. Details of these research will be presented in this paper. | ||
![]() |
Slides TUYGBE3 [2.219 MB] | |
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-TUYGBE3 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
TUPMF020 | Demonstration of Fast, Single-shot Photocathode QE Mapping Method Using MLA Pattern Beam | 1293 |
|
||
Funding: UChicago Argonne, LLC, Operator of Argonne National Laboratory ("Argonne"). Argonne, a U.S.A. Department of Energy Office of Science laboratory, is operated under Contract No. DE-AC02-06CH11357. Quantum efficiency (QE) is the chief figure of merit in the characterization of photocathodes. Semiconductor photocathodes, especially when used in high rep-rate photo-injectors, are known to show QE degradation over time and must be replaced. The total QE is the basic diagnostic which is used widely and is easy to obtain. However, a QE map indicating variations of QE across the cathode surface has greater utility. It can quickly diagnose problems of QE inhomogeneity. Most QE mapping techniques require hours to complete and are thus disruptive to a user facility schedule. A fast, single-shot method has been proposed (citation) using a micro-lens array (MLA) generated QE map. In this paper we report the implementation of the method at Argonne Wakefield Accelerator facility. A micro-lens array (MLA) is used to project an array of beamlets onto the photocathode. The resulting photoelectron beam in the form of an array of electron beamlets is imaged at a YAG screen. Four synchronized measurements are made and the results used to produce a QE map of the photocathode. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-TUPMF020 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
TUPML004 | Correction of Emittance Growth Due to Quad Components in Solenoids With Quad Correctors at AWA | 1536 |
|
||
An asymmetrical electron beam is observed on the drive beamline at Argonne Wakefield Accelerator (AWA) due to the quad components in the solenoids. An ASTRA simulation shows that the emittance will increase when the electron beam passes through solenoids with quad errors. We use two quad correctors to correct this emittance growth. A preliminary emittance correction result is presented in this paper. | ||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-TUPML004 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
TUPML006 | Updates of the Argonne Cathode Test-stand | 1542 |
|
||
The Argonne Cathode Test-stand (ACT) is a unique testbed to develop cathodes and to conduct fundamental surface study under ultra-high rf field (up to 700 MV/m with pin-shaped cathodes). The test-stand consists of an L-band 1.3 GHz single-cell photocathode rf gun and a field emission (FE) imaging system to locate emitters with a resolution of ∼20 𝜇m. In the recent upgrade, UV laser has been introduced to improve the imaging system and to significantly expand the ACT towards photoemission and laser-assisted field emission research. In addition, a load-lock system has been added to the beam line to expedite the cathode switching period. The paper will present details of the upgrade as well as experiments planned in the near future. | ||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-TUPML006 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
TUPML007 | Short Pulse High Power RF Generation with an X-Band Dielectric Power Extractor | 1546 |
|
||
Short pulse high power rf generation is one of the key technologies for the Argonne Flexible Linear Collider (AFLC), a proposed 3 TeV electron-positron linear collider based on two-beam acceleration (TBA) scheme. Compared with metallic power extractors, dielectric structures have the potential to achieve lower fabrication cost and to withstand higher gradient. Recently, an X-band dielectric power extractor (a.k.a, DPETS) has been developed at the Argonne Wakefield Accelerator (AWA) facility and achieved 105 MW output power when driven by a high charge 8-bunch train separated by 770 ps. The design, the cold test measurement, the preliminary high power test results, and the structure inspection will be presented in this paper. | ||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-TUPML007 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
THXGBE3 |
Proof of Principle Experiment for Single Shot Transverse Phase Space Measurement | |
|
||
Funding: Department of Energy, Office of HEP and BES under Contract No. DE-AC02-06CH11357. We introduce a new method for single-shot transverse phase-space measurement. Existing phase space measurement methods are based on either average multiple shots of the full beam (e.g. scanning slit and quad scan tomography) or a single-shot sample of the beam (e.g. pepper pot and multi-slit). To achieve a single-shot measurement of the full beam, we project the beam's x-coordinate to the y-coordinate and its x'-coordinate to the x-coordinate using a skew quadrupole magnet followed by a normal quadrupole magnet. We present a theoretical description of this projection scheme and a proof-of-principle experimental demonstration done at the Argonne Wakefield Accelerator facility. |
||
![]() |
Slides THXGBE3 [2.904 MB] | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |