Paper | Title | Page |
---|---|---|
TUPAL033 | Time-of-Flight, Beam-Energy Measurement of the LANSCE 805-MHz Linac | 1075 |
|
||
Funding: Work supported by the United States Department of Energy, National Nuclear Security Agency, under contract DE-AC52-06NA25396. Control of the beam-energy ramp along the length of a proton linear accelerator is required to keep the accelerator tuned according to design. Historically, the values of the field amplitudes and phases of the side-coupled, 805-MHz LANSCE linac modules are maintained using a well-known delta-t tuning procedure*. Time-of-flight measurements of the proton beam energy are now also being used to confirm and improve the overall control of the energy ramp along the linac. The time-of-flight method uses measurements of the difference in RF phases measured as the beam passes installed delta-t pickup loops. A newly developed chassis to control the 3D position of the beam centroid is used. Details of the procedure and results of measurements are presented. * K.R.Crandall, "The Delta-T Tuneup Procedure for the LAMPF 805-MHz Linac", LANL Report LA-6374-MS, June 1976. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-TUPAL033 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
TUPAL034 | Effect of 805-MHz Linac RF Stability on Beam Losses in LANSCE High-Energy Beamlines | 1078 |
|
||
Funding: Work supported by the United States Department of Energy, National Nuclear Security Agency, under contract DE-AC52-06NA25396. Operation of an accelerator facility critically depends on stability of the field amplitudes and phases of the accelerating cavities. The LANSCE linear accelerator consists of a 201.25-MHz, drift-tube linac and an 805-MHz, side-coupled-cavity linac (SCL). Beam losses in the high-energy beamlines of the 800-MeV facility were measured versus variation of the amplitudes and phases of the 805-MHz, SCL, RF cavities. A recent study* confirms that to achieve low losses, the stability of the amplitudes and phases should be kept within 0.1% and 0.1o, respectively. This agrees with a previous study of beam losses in the 201.25-MHz linac. Details of the measurements and results are presented. *L.J.Rybarcyk, R.C.McCrady, Proceeding of LINAC2016, East Lansing, MI, USA, MOPLR072, p.301. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-TUPAL034 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |