The superconducting heavy ion synchrotron SIS100 of the FAIR-facility will be equipped with 60 cryocatcher, to suppress dynamic vacuum effects. A prototype cryocatcher has been designed, manufactured and underwent several tests. The results yielded in the design of the series cryocatcher. Recently, the First-of-Series cryocatcher has been manufactured and tested. Results from the manufacturing process and the site acceptance tests, including cryogenic test with liquid helium are presented. The FoS cryocatcher sucessfully passed all tests and the series production will be released.
|
|