MOPP002 |
Current Per Bunch Distribution Measurement at ESRF |
SRF, ECR, controls, injection |
59 |
|
- L. Torino, B. Roche, B. Vedder
ESRF, Grenoble, France
|
|
|
During the last run of the ESRF machine, several instrumentation improvements have been carried out in order to be exported on the new EBS storage ring. In particular, the top-up operation mode has been implemented and it demanded for an accurate, fast, and reliable measurement of the current per bunch distribution. In this proceeding, we describe the characteristics and the performance of the setup chosen to perform this measurement, which consists in a stripline, connected with a high dynamic range oscilloscope and a dedicated data analysis. We also comment on the integration of the measurement in the top-up routine to selectively refill less populated bunches.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IBIC2019-MOPP002
|
|
About • |
paper received ※ 03 September 2019 paper accepted ※ 08 September 2019 issue date ※ 10 November 2019 |
|