Keyword: brilliance
Paper Title Other Keywords Page
WEPP005 BPM Resolution Studies at PETRA III electron, electronics, optics, pick-up 517
 
  • G. Kube, J. Neugebauer, F. Schmidt-Föhre
    DESY, Hamburg, Germany
 
  In order to measure the noise level of a BPM system from beam generated orbit data, the correlated beam jitter has to be removed from the position signals. There exist different ways to extract the BPM noise, as the "three-BPM" correlation method or the model-independent principal components analysis (PCA). Both methods will shortly be reviewed. Based on a PCA, the resolution of the PETRA III Libera Brilliance based BPM system was measured. The results will be presented together with first measurements in view of an updated BPM system for the future PETRA IV project at DESY.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IBIC2019-WEPP005  
About • paper received ※ 02 September 2019       paper accepted ※ 10 September 2019       issue date ※ 10 November 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)