Author: Reiter, A.
Paper Title Page
MOPP005 Radiation hardness investigation of Zinc oxide fast scintillators with relativistic heavy ion beams. 71
 
  • P. Boutachkov, A. Reiter, M. Saifulin, B. Walasek-Höhne
    GSI, Darmstadt, Germany
  • E.I. Gorokhova
    GOI, St Petersburg, Russia
  • P. Rodnyi, I.D. Venevtsev
    SPbPU, St. Petersburg, Russia
 
  At GSI ion beams of many elements, from H up to U, are produced with energy as high as 4.5 GeV/u with the SIS-18 synchrotron. For absolute beam intensity and micro-spill structure measurements a BC400 organic scintillator is used. Due to the low radiation hardness of this material, alternative inorganic scintillators like ZnO:Ga and ZnO:In were investigated. The properties and possible application of these novel radiation hard fast scintillators will be discussed. Their response to Sn, Xe and U ion beams will be reported.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IBIC2019-MOPP005  
About • paper received ※ 04 September 2019       paper accepted ※ 09 September 2019       issue date ※ 10 November 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPP037 Status of Beam Instrumentation for FAIR HEBT 193
 
  • M. Schwickert, P. Boutachkov, T. Hoffmann, H. Reeg, A. Reiter, B. Walasek-Höhne
    GSI, Darmstadt, Germany
 
  At present the Facility for Antiproton and Ion Research (FAIR) is under construction at the GSI site. As part of the FAIR project the beamlines of the High Energy Beam Transport (HEBT) section interconnect the synchrotrons, storage rings and experimental caves. The large range of beam energies (MeV to GeV) and beam intensities up to 1012 particles per pulse for uranium, or up to 2·1013 particles per pulse for protons, demand in many cases for purpose-built beam diagnostic devices. Presently, the main diagnostic components are being manufactured by international in-kind partners in close collaboration with GSI. This contribution presents an overview of the beam instrumentation layout of the FAIR HEBT and summa-rizes the present status of developments for HEBT beam diagnostics. We focus on the status of the foreseen beam current transformers, particle detectors, scintillating screens and profile grids.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IBIC2019-MOPP037  
About • paper received ※ 04 September 2019       paper accepted ※ 07 September 2019       issue date ※ 10 November 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)