Paper | Title | Page |
---|---|---|
TUPTEV011 | SRF Accelerating Modules Repair at DESY | 508 |
|
||
Eight SRF cavities assembled in an accelerating module represent a building block of the particle linear accelerator based on TESLA SRF technology. DESY has two machines, European XFEL and FLASH. Both use almost same module and cavity types. During the module assembly many factors can deteriorate the cavity performance and cause a need for a repair action. Currently two European XFEL modules and two FLASH ones underwent reassembly procedures. The repair was not immediately successful on every of these modules and re-iterations did follow. The degradation causes were investigated. SRF modules were tested on both test-stands at DESY: AMTF and CMTB. The results of the described actions are presented and discussed. | ||
![]() |
Poster TUPTEV011 [1.499 MB] | |
DOI • | reference for this paper ※ doi:10.18429/JACoW-SRF2021-TUPTEV011 | |
About • | Received ※ 18 June 2021 — Accepted ※ 19 November 2021 — Issue date ※ 01 February 2022 | |
Cite • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |