Author: Mitsunobu, S.
Paper Title Page
TUPFAV002 Calibration of SRF Cavity Voltage by Measurement of Synchrotron Frequency in SuperKEKB 376
 
  • M. Nishiwaki, K. Akai, T. Furuya, T. Kobayashi, S. Mitsunobu, Y. Morita, T. Okada
    KEK, Ibaraki, Japan
 
  Eight SRF cavity modules, which have been operated in KEKB for more than ten years, are stably operating also in SuperKEKB. As for calibration of the cavity voltage Vc, non-negligible discrepancy was observed between the results obtained from two different methods: one is using external Q value (Qext) of pickup ports, and the other is using loaded Q value (QL) of the cavities. The discrepancy comes from inaccuracy of power measurement in high power RF system and uncertainty of the Qext or QL values. In order to solve the discrepancy by improving the accuracy of the calibration for each individual cavity, we investigated a method by measuring synchrotron frequency fs of stored beam. With this method, Vc calibration can be performed without affected by inaccuracy of high-power measurement or uncertainty of the Qext or QL values. The fs measurement studies were carried out in SuperKEKB. With these studies, Vc calibration was obtained with a high accuracy of about 1%. The results are applied to the SuperKEKB operation.  
DOI • reference for this paper ※ doi:10.18429/JACoW-SRF2021-TUPFAV002  
About • Received ※ 21 June 2021 — Revised ※ 13 August 2021 — Accepted ※ 21 August 2021 — Issue date ※ 14 October 2021
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)