Superconducting RF Performance of Cornell 500 MHz N-Doped B-Cell SRF Cavitiy |
764 |
|
- M. Ge, T. Gruber, A.T. Holic, M. Liepe, J. Sears
Cornell University (CLASSE), Cornell Laboratory for Accelerator-Based Sciences and Education, Ithaca, New York, USA
|
|
|
The Cornell SRF group is working on rebuilding a 500 MHz B-cell cryomodule (CRYO-2 BB1-5) as a spared cryomodule for the operation of the CESR ring. To minimize BCS surface resistance, achieve a high quality-factor (Q0), and increase maximum fields, we prepared the cavity’s surface with electropolishing and performed a 2/6 N2-doping. In this work, we report 4.2 K and 2 K cavity test results with detailed surface resistance analysis, showing improved performance, including significant higher fields.
|
|
|