Author: Gruber, T.
Paper Title Page
THPFDV005 Superconducting RF Performance of Cornell 500 MHz N-Doped B-Cell SRF Cavitiy 764
 
  • M. Ge, T. Gruber, A.T. Holic, M. Liepe, J. Sears
    Cornell University (CLASSE), Cornell Laboratory for Accelerator-Based Sciences and Education, Ithaca, New York, USA
 
  The Cornell SRF group is working on rebuilding a 500 MHz B-cell cryomodule (CRYO-2 BB1-5) as a spared cryomodule for the operation of the CESR ring. To minimize BCS surface resistance, achieve a high quality-factor (Q0), and increase maximum fields, we prepared the cavity’s surface with electropolishing and performed a 2/6 N2-doping. In this work, we report 4.2 K and 2 K cavity test results with detailed surface resistance analysis, showing improved performance, including significant higher fields.  
poster icon Poster THPFDV005 [0.718 MB]  
DOI • reference for this paper ※ doi:10.18429/JACoW-SRF2021-THPFDV005  
About • Received ※ 05 July 2021 — Revised ※ 10 August 2021 — Accepted ※ 21 August 2021 — Issue date ※ 22 April 2022