Author: Collier, G.
Paper Title Page
MOPFAV002 Commissioning of the UKRI STFC Daresbury Vertical Test Facility for Jacketed SRF Cavities 308
 
  • A.J. May, A.E.T. Akintola, A.R. Bainbridge, R.K. Buckley, G. Collier, P.A. Corlett, K.D. Dumbell, M.J. Ellis, S. Hitchen, P.C. Hornickel, G. Hughes, C.R. Jenkins, P.A. McIntosh, K.J. Middleman, A.J. Moss, N. Pattalwar, S.M. Pattalwar, M.D. Pendleton, P.A. Smith, A.E. Wheelhouse, AAJ. White, S. Wilde
    STFC/DL/ASTeC, Daresbury, Warrington, Cheshire, United Kingdom
  • M.D. Hancock, J. Hathaway, C. Hodgkinson, G. Jones, M. Lowe, D.A. Mason, G. Miller, J. Mutch, A. Oates, P. Sollars, J.T.G. Wilson
    STFC/DL, Daresbury, Warrington, Cheshire, United Kingdom
 
  A novel vertical test facility has been developed at the STFC Daresbury Laboratory. The VTF is designed to test 3 jacketed SRF cavities in a horizontal configuration in a single cool-down run at 2 K. Cavities were tested at low power levels for HOMs and passband modes, and Q vs E field measurements at high power levels. The specification requires an unloaded Q of 5·109 at a field gradient of 19.9 MV/m. The cavities are cooled with superfluid helium filled into their individual helium jackets. This reduces the liquid helium consumption by more than 70% in comparison with the conventional facilities operational elsewhere. The facility will be used to conduct a 2-year program to qualify 84 high-beta SRF cavities for the European Spallation Source as part of the UK’s in-kind contribution. This paper reports on the commissioning program, along with a detailed discussion of the RF and cryogenic operations and performance of the facility.  
DOI • reference for this paper ※ doi:10.18429/JACoW-SRF2021-MOPFAV002  
About • Received ※ 21 June 2021 — Revised ※ 12 July 2021 — Accepted ※ 21 August 2021 — Issue date ※ 20 October 2021
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)