Design and Manufacturing Challenges of the SSR1 Current Leads for PIP-II |
cryomodule, focusing, vacuum, cryogenics |
329 |
|
- S. Cheban, D. Passarelli, V. Roger
Fermilab, Batavia, Illinois, USA
|
|
|
The SSR1 cryomodule contains eight 325 MHz superconducting single spoke cavities and four solenoid-based focusing lenses operating at 2 K. The focusing lens for SSR1 cryomodule, is a superconducting magnet surrounded by a helium box which will be filled with liquid helium. The magnet assembly is composed of one solenoid with operating current 70 A and 2 quadrupoles correctors with operating current 45 A. The conduction cooled current leads will be used to power magnets. The details of current leads design, fabrication and room temperature qualification will be presented. Main emphasis will be put on the design and production process challenges and possible solutions to fulfilled operation requirement under low temperature conditions.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-SRF2019-MOP101
|
|
About • |
paper received ※ 28 June 2019 paper accepted ※ 30 June 2019 issue date ※ 14 August 2019 |
|