2 K SUPERFLUID HELIUM CRYOGENIC VERTICAL TEST STAND OF PAPS |
1107 |
|
- L.R. Sun, R. Ge, R. Han, Y.C. Jiang, S.P. Li, C.C. Ma, M.J. Sang, M.F. Xu, R. Ye, J.H. Zhang, X.Z. Zhang, Z.Z. Zhang, T.X. Zhao
IHEP, Beijing, People’s Republic of China
|
|
|
Platform of Advanced Photon Source Technology R&D (PAPS) in the Institute of High Energy Physics (IHEP) is an ongoing project, which aimed to provide a comprehensive research and testing platform for the particle accelerator, X-ray detection and optics. As one of the important parts of the platform, cryogenic vertical test stand for the superconducting cavities is composed of three big vertical test cryostats with 2 different inner diameters, which can provide 4.5K liquid helium, 2K superfluid helium and the lowest 1.5K environments according to the cavities test requirements. The cryogen-ic vertical test stands also focus on current international ¿hot spot¿ fast cool down to the superconducting cavi-ties, maximum liquid helium mass flow rate can be reached to 80g/s. Because of the big size of the cryostats and certain scale, the finished cryogenic vertical test stand can meet several different type cavities test, such as 1.3GHz 9cell, Spoke, elliptical, etc. And also can provide the cavities¿ mass vertical testing for the large scale superconducting accelerators.
|
|
|