Author: Ryzhov, A.A.
Paper Title Page
THP032 SRF Gun and SRF Linac Driven THz at ELBE Successfully in User Operation 915
 
  • R. Xiang, A. Arnold, P.E. Evtushenko, S. Kovalev, U. Lehnert, P.N. Lu, S. Ma, P. Michel, P. Murcek, A.A. Ryzhov, J. Schaber, Ch. Schneider, J. Teichert
    HZDR, Dresden, Germany
  • H. Vennekate
    RI Research Instruments GmbH, Bergisch Gladbach, Germany
  • I. Will
    MBI, Berlin, Germany
 
  Funding: The work was partly supported by the German Federal Ministry of Education and Research (BMBF) grant 05K12CR1 and Deutsche Forschungsgemeinschaft (DFG) project (XI 106/2-1).
The first all-SRF accelerator driven THz source has been operated as a user facility since 2018 at ELBE radiation center. The CW electron beam is extracted from SRF gun II, accelerated to relativistic energies and compressed to sub-ps length in the ELBE SRF linac with a chicane. THz pulses are produced by pass-ing the short electron bunches through a diffraction radiator (CDR) and an undulator. The coherent THz power increases quadratically with bunch charge. The pulse energy up to 10 µJ at 0.3 THz with 100 kHz has been generated.
 
poster icon Poster THP032 [1.207 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-SRF2019-THP032  
About • paper received ※ 02 July 2019       paper accepted ※ 04 July 2019       issue date ※ 14 August 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THP083 Quadrupole Scan Transverse Emittance Measurements at HZDR ELBE 1100
SUSP028   use link to see paper's listing under its alternate paper code  
 
  • S. Ma, A. Arnold, A.A. Ryzhov, J. Schaber, J. Teichert, R. Xiang, K. Zhou
    HZDR, Dresden, Germany
 
  Two quadrupoles and one screen are used for beam transverse emittance measurements at HZDR ELBE. In this paper, the emittance calculated with two different methods, one with thin-lens approximation and the other one without this approximation, are compared and analized. To analyze the measurement error, quadrupole calibration is need. Two aspects about quadrupole analysis are made. The first one is quadrupole¿s effective length and strength and the second one is quadrupole¿s converged or diverged ability in reality.  
poster icon Poster THP083 [1.726 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-SRF2019-THP083  
About • paper received ※ 25 June 2019       paper accepted ※ 03 July 2019       issue date ※ 14 August 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)