Author: Mueller, P.    [Müller, P.]
Paper Title Page
MOP019 Surface Preparation and Optimization of SC CH Cavities 71
SUSP024   use link to see paper's listing under its alternate paper code  
 
  • P. Müller, M. Basten, M. Busch, T. Conrad, H. Podlech
    IAP, Frankfurt am Main, Germany
  • K. Aulenbacher, F.D. Dziuba, M. Miski-Oglu
    HIM, Mainz, Germany
  • W.A. Barth
    GSI, Darmstadt, Germany
 
  The Institute of Applied Physics (IAP) introduced the superconducting multi-gap CH-structure, which is mainly designed for low beta hadron acceleration. In 2017, a 217 MHz sc CH-structure was successfully tested with beam at GSI and multiple CH-structures are currently under development for the GSI cw linac. RF performance of all sc cavities are limited by the surface properties of the used material. Therefore, sufficient surface preparation and optimization is necessary to achieve optimal performance. Presently as standard procedure BCP and HPR is used for CH-cavities. Several surface treatments will be applied to the very first CH-prototype, a 360 MHz, 19-cell cavity. Prior to the first treatment, the status of the cavity was examined, including leak tests and performance tests at 4 and 2 K. This paper presents the performance development of a sc CH cavity depending on different preparation methods.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-SRF2019-MOP019  
About • paper received ※ 23 June 2019       paper accepted ※ 05 July 2019       issue date ※ 14 August 2019  