Author: Hernandez-Chahin, K.
Paper Title Page
THP078 CERN’s SRF Test Stand for Cavity Performance Measurements 1082
 
  • N. Stapley, J. Bastard, M.R. Coly, A.E. Ivanov, A. Macpherson, N.C. Shipman, K. Turaj
    CERN, Geneva, Switzerland
  • I. Ben-Zvi
    BNL, Upton, New York, USA
  • A. Castilla
    Cockcroft Institute, Lancaster University, Lancaster, United Kingdom
  • K. Hernandez-Chahin
    Universidad de Guanajuato, División de Ciencias e Ingenierías, León, Mexico
  • M. Wartak, A. Zwozniak
    IFJ-PAN, Kraków, Poland
 
  Recent deployment of a digital LLRF system within the cavity testing framework of CERN’s vertical test cryostats has permitted a full revamp of cavity performance validation. With both full continuous and pulse mode operation, steady state a transient RF behaviour can be effectively probed. Due to direct and integrated control and monitoring of environmental test conditions, standard and novel RF measurement procedures have been developed and integrated into the testing infrastructure, along with a coherent data flow of high granularity measurement data. We present an overview of this cavity measurement system and address the underlying architectural structure, data handling and integration of user interfaces. In addition we highlight the benefits of variety of RF cavity measurements that can now be accommodated in our large 2 K cryostats.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-SRF2019-THP078  
About • paper received ※ 23 June 2019       paper accepted ※ 30 June 2019       issue date ※ 14 August 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)