Paper |
Title |
Page |
MOPB007 |
Design of the Superconducting Quarter Wave Resonators for HIAF |
59 |
|
- C. Zhang, L. Chen, Q.W. Chu, H. Guo, Y. He, S.C. Huang, Y.L. Huang, T.C. Jiang, L. Li, Y.M. Li, F. Pan, T. Tan, R.X. Wang, A.D. Wu, Q.J. Wu, P.R. Xiong, W.M. Yue, S.H. Zhang, S.X. Zhang
IMP/CAS, Lanzhou, People's Republic of China
|
|
|
A heavy ion accelerator facility (HIAF) is under development in the Institute of Modern Physics. For the low energy superconducting accelerating section, two types of quarter wave resonators with frequency of 81.25 MHz and β of 0.05 and 0.10 have been proposed. The electro-magnetic design has been optimized in order to reach the high accelerating voltage, and the optimization also included the drift tube face tilting to compensate for the beam steering caused by the asymmetry in the quarter wave resonator geometry.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-SRF2017-MOPB007
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
TUPB039 |
Electropolishing of Niobium from Deep Eutectic Solvents Based on Choline Chloride |
475 |
|
- Q.W. Chu, H. Guo, Y. He, L. Li, P.R. Xiong, Z.M. You, S.H. Zhang
IMP/CAS, Lanzhou, People's Republic of China
|
|
|
Niobium (Nb) was successfully electropolished from a green ionic liquid, choline chloride/urea deep eutectic solvent (DES). This paper was to investigate the influence of various electropolishing parameters, including electropolishing time, temperature and voltage, on the electropolishing rate, surface roughness, glossiness and microstructure of Nb. The result showed that the electropolishing parameters had a significant impact on the performance of Nb. Based on surface analysis by scanning electron microscope (SEM) and atomic force microscope (AFM), smooth Nb can be achieved under properly controlled conditions.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-SRF2017-TUPB039
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
TUPB112 |
First Test of Electropolishing System at IMPCAS |
660 |
|
- L. Li, Q.W. Chu, H. Guo, Y. He, P.R. Xiong, Z.Q. Yang, Z.M. You, B. Zhang, S.H. Zhang, X. Zhu
IMP/CAS, Lanzhou, People's Republic of China
|
|
|
The first SRF cavity electropolishing system of China has been built by IMPCAS. We used two type of cathodes in different process parameters to test the typical Voltage-Current Density curves of 1.3GHz one-cell SRF cavity.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-SRF2017-TUPB112
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|